The design, fabrication and testing of a new in-field measurement setup of an electronic nose sensor for early plant disease detection

Crop losses caused by plant diseases and pest infestations are an increasing global challenge. Current crop-management strategies frequently depend on visual inspection, manual scouting, and the removal or treatment of visibly infected plants. However, visual symptoms often appear only after disease or pest stress has progressed. Plants can emit characteristic volatile organic compounds (VOCs) in response to biotic stress, including pathogen infection, herbivory, and pest infestation. Monitoring changes in plant VOC profiles, therefore, offers a promising, non-destructive approach for the early detection of plant stress before visible symptoms occur.

Capacitive gas sensing is a promising method for VOC monitoring because the adsorption of gas molecules onto a functional sensing layer can change its dielectric properties. These changes modify the capacitance of the underlying electrode structure and can be measured electronically. In previous laboratory work, the capacitive sensing principle was successfully demonstrated under controlled exposure conditions using defined VOC concentrations. The laboratory setup enabled stable sensor characterization, comparison of different functional materials, and evaluation of the sensing platform's discrimination capability. However, laboratory-based measurements do not fully represent realistic agricultural environments, where VOC concentrations, temperature, humidity, airflow, plant density, and background VOC profiles can change continuously.

To the best of our knowledge, this work presents the first demonstration of a CMOS-pixelated capacitive gas-sensing platform designed for portable in-field VOC measurements. The system functions as an electronic nose (E-nose) and is based on a complementary metal--oxide--semiconductor (CMOS) chip containing an array of 1024 capacitive microelectrodes. Each microelectrode, referred to as a pixel, can act as an individual capacitive sensing element. The high pixel density enables multiple different sensing materials to be deposited across the same chip, creating a chemically diverse sensor array within a compact device footprint.

The CMOS pixels were functionalized by capillary-based microprinting using a Sonoplot dispensing system. This printing method enables controlled deposition of small volumes of sensing inks directly onto selected sensor pixels. It therefore allows different materials to be patterned spatially across the chip and supports repeatable fabrication of a multi-material sensing array. The functional materials included the metal--organic frameworks (MOFs) CAU-10 and CAU-23, carbon-black ink, a copper-based Prussian blue analogue (CuPBA), and UV-curable ink. These materials were selected to introduce distinct chemical interactions with VOC molecules, thereby creating different response behaviors across the pixel array. CAU-10, CAU-23, CuPBA, carbon-black ink, and UV-curable ink provide diverse porous, conductive, and polymeric sensing layers, creating chemically distinct microdomains with different VOC adsorption and capacitance responses.

The material-functionalized CMOS capacitive E-nose was first evaluated under controlled laboratory conditions using reproducible VOC concentrations. The sensor array differentiated three of twelve tested VOCs, demonstrating selective response patterns and providing calibration data for subsequent predictive modeling and classification.

Building on the laboratory validation, this project developed a portable in-field measurement setup to transfer the capacitive E-nose from controlled laboratory experiments to realistic plant-monitoring applications. The system enables autonomous measurements in greenhouses, with potted plant samples, and in open-field environments by using an air-sampling pump and adjustable tubing to collect VOC-containing air from selected plant areas and transport it to the sensor chamber. The tubing configuration can be adapted to control the sampling position, distance, airflow path, and exposure duration for different plant species, greenhouse layouts, and field conditions. Rather than simply exposing the sensor to ambient air, the platform provides controlled VOC sampling and transportation to the functionalized sensor surface, improving measurement reproducibility and enabling comparison between laboratory-calibrated response profiles and measurements under real agricultural conditions.

In future work, the platform can be trained on target VOCs relevant to greenhouse horticulture, such as methyl salicylate, a potential indicator of herbivory or spider-mite infestation, and octyl hexanoate, a potential semiochemical marker associated with Nesidiocoris tenuis. Laboratory calibration using known VOC concentrations can be used to develop predictive models prior to deployment. The sensor can subsequently be tested under progressively more realistic conditions, including controlled plant chambers, entomological cages, walk-in cages, and greenhouse compartments. The combination of a portable sampling setup, a 1024-pixel CMOS capacitive E-nose, inkjet or capillary-printed functional materials, and data-driven response analysis provides a scalable route towards early pest and disease detection, spatial VOC monitoring, and precision crop management.
...
Master thesis (2026) - N.D. Pittroff, M.K. Ghatkesar
Neural implants are battery-powered electrical devices whose electrodes are placed on nerves in the brain and stimulate them via electrical signals. They are used to treat Parkinson’s disease and drug-resistant epilepsy, and they remain in the body for years. The electrodes sit on the brain, while the battery is sealed in a rigid housing placed in a pocket in the chest. Body tissue is soft and moves, therefore the rigid housing and the leads connecting it to the electrodes create a mechanical mismatch and can inflame the tissue and damage nearby cells. Furthermore, the finite battery life requires additional replacement surgery increasing infection risks and health care costs. A soft carrier would allow a smaller, leadless implant, with the stimulus produced at the nerve directly. Piezoelectric ceramics are a suitable option to create these implants, as a deformation of the ceramic produces an electrical signal. Pressure changes in the body can supply that deformation, enabling the implant to stimulate the nerves without an external power source. However, growing crystalline oxides require a single crystal substrate and harsh growing conditions that flexible substrates cannot provide, making them difficult to integrate. Flexible electronics are already addressing parts of this integration challenge using sacrificial substrates to grow piezoelectric oxides on and move them onto a flexible substrate after. However, joining the oxide and integrating it with the electrical connections so the stack stays intact and bonded to the substrate remains difficult. This thesis establishes a fabrication route for that stack. A gold electrode is transferred onto a flexible polydimethylsiloxane membrane, and a barium titanate film, covered with gold, is released from its growth wafer and transferred onto that electrode. The fabrication route was established by optimizing the pulsed-laser deposition of the thin films, adding support during release and transfer, and developing a stable method to transfer gold to the soft polymer. ...
Bulk analysis masks cell-to-cell heterogeneity, whereas single-cell tools like Fluidic Force Microscopy (FluidFM) resolve individual signals. However, sequential multi-cell sampling requires probe replacement or washing to prevent diffusive mixing. Dual-channel segmented aspiration addresses this by isolating extracts with an immiscible phase, but reported minimum volumes (170 pL) remain far larger than typical mammalian cells (2-15 pL).
In this project, capillary pinning is leveraged for state-determined flow segmentation in a microfluidic AFM cantilever. Two channels meet at a T-junction delimited by geometric burst valves (GBVs) to decouple segmentation from actuation pulse duration, while an additional GBV defines the sample volume. The design was confirmed using a two-phase COMSOL model validated against analytical Young-Laplace predictions. The device was fabricated using multi-scale 3D printing, which combines digital light processing (DLP) used for printing the fluidic interface, and two-photon polymerisation (2PP) for printing the cantilever. Structural modelling validated against Laser Doppler Vibrometry (LDV) yielded an estimated cantilever stiffness of 1.12 N/m. Mounted on an AFM platform with a dual-channel pressure controller, the probe aspirated up to nine consecutive water samples using air as a separator phase. Optically estimated segmented volumes were 6.35 ± 0.37 pL (0.16% deviation from the 6.36 pL design volume; 5.8% relative standard deviation). This advances volume resolution beyond existing segmented probes while preserving AFM force-displacement curve acquisition. ...
Suspended microchannel resonators (SMRs) enable fast and accurate mass measurements of micro- and nanoparticles in liquid. By confining the fluidic sample within a microchannel located in a vacuum environment, SMRs eliminate viscous damping to achieve high sensitivity. Because the minimum detectable mass is directly proportional to the resonator’s effective mass, reducing the structural mass is critical for analyzing smaller particles. This study presents a novel fabrication methodology for ultralight SMRs. A 93 nm thick CVD/ALD (SiNx/AlOx) nanomembrane is self-rolled into a tube with a 10.6 μm diameter and suspended over a 100 μm length. This CMOS-compatible approach bypasses traditional III-V materials and entirely eliminates capillary stiction failures by utilizing a PI-2610 sacrificial layer alongside an isotropic dry-etch release. The suspended microtubes were mechanically characterized in a custom vacuum chamber (2 × 10−5 mbar at 20°C) using laser Doppler vibrometry. Dynamically, the fabricated device operates as a rigid mass supported by fixed-guided suspension beams (5 μm long, 4 μm wide, 93 nm thick). Vibrometry revealed a fundamental eigenfrequency of 39.123 kHz with a mechanical quality factor of 1138. These results validate a highly scalable platform for 3D suspended structures, paving the way for future microfluidic integration and advanced nanoparticle detection. ...
Cryo-Electron Microscopy (Cryo-EM) enables high-resolution bio-molecular imaging but is limited by inconsistent vitrified ice thickness and quality during sample preparation. This thesis develops MEMS-based Electrical Impedance Spectroscopy (EIS) as a rapid, non-destructive method to extract quantitative thickness information from thin liquid and ice layers prior to vitrification. Numerical simulations in COMSOL Multiphysics, supported by analytical parallel-plate and equivalent-circuit models, demonstrate that measurable impedance variations emerge for dielectric layers in the 50–500 nm range under idealized conditions, with monotonic and near-linear relationships between impedance-derived metrics and layer thickness over selected frequency windows. Experimental validation using fabricated MEMS sensor chips by DENSsolutions and white-light interferometry for ground-truth thickness confirm that EIS measurements demonstrate qualitative agreement in impedance–thickness correlation for liquid water, as impedance measurements can be reliably calibrated to thickness with repeatable trends and nanometer-scale sensitivity. Overall, this study demonstrates that MEMS-based EIS is a feasible and scalable approach for quantitative pre-vitrification thickness monitoring in cryo-EM workflows, offering a pathway toward reduced trial-and error grid screening and improved reproducibility, while clearly identifying the remaining experimental and calibration challenges required for practical deployment. ...
Early detection of plant diseases is crucial to minimize crop losses and reduce the usage of pesticides. Electronic Nose (E-Nose) detect volatile organic compounds (VOCs) emitted by stressed or diseased plants, and one such device is a pixelated capacitive sensor (PCS). We designed and built a setup to investigate the influence of light (wavelength and intensity) on the sensitivity of a functionalized PCS for VOCs detection. Our test results indicate that UV illumination, particularly at 375 nm, enhances the sensitivity of the PCS, with a 3-fold enhancement compared to dark conditions. The sensor showed fast saturation (<1 min) and recovery (<2 min) times, confirming the effectiveness of the chamber design for repeatable gas exposure. ...
Master thesis (2024) - Q. Wang, T. Manzaneque Garcia, M.K. Ghatkesar
Resonant mass sensors are emerging as innovative instruments for particle measurement, which utilize the resonance frequency shifts of oscillatory structures. Micro- and nano-pillars have been adopted as the resonators for the high sensitivity of this mass sensing technique. However, existing frequency measurement methods for micro- and nano-mechanical resonators are mostly based on piezoresistive readouts, which were challenged for the integration of such small structures as submicron pillars. In this paper, aluminum nitride surface acoustic wave (SAW) delay line devices were utilized to investigate the potential for measuring the resonance frequencies of several micro/nano-pillars simultaneously. SAW delay line devices for this resonance measuring application have been successfully designed, fabricated, and tested. Both two-photon polymerized (TPP) pillars and focused ion beam (FIB) deposited pillars have been incorporated into the delay line devices. COMSOL simulations in this work have demonstrated the feasibility of multi-resonance measurements. Small peaks, likely corresponding to pillar resonances, were detected and showed some correlation with the resonances. These results suggest that using SAW delay lines is a promising technique for multi-resonance detection of nanopillar arrays. This work paved the way for high-sensitivity
mass sensor development with effective SAW devices and methods of incorporating pillars. ...
Master thesis (2024) - J.J. Mens, Murali Ghatkesar
Subcellular biopsy (SCB) using atomic force microscopy (AFM) with a microfluidic cantilever enables the extraction of biological samples from living cells. Traditional cryo-electron microscopy (cryo-EM) sample preparation methods are unsuitable for the small volumes from SCB. This study presents a novel method to prepare cryo-EM samples directly from SCB samples, integrating dispensing, thickness measurement, and local temperature control to minimize evaporation. The method uses a microfluidic AFM cantilever for dispensing, a Mach-Zehnder interferometer for real-time thickness measurement, and plunge freezing for vitrification. The system successfully demonstrated dispensing picoliter droplets, with potential for femtoliter volumes. The temperature-controlled grid holder reduced evaporation rates, allowing sufficient time for real-time thickness measurement. The system has demonstrated the required transition speed and plunge velocity. Initial cryo-EM thickness measurements demonstrate the method's potential. In conclusion, a novel system for subcellular biopsy sample preparation for cryo-EM was designed, fabricated, and tested. It maintains picoliter sample volumes on a temperature-controlled EM grid, enabling real-time thickness measurement and immediate plunge freezing. ...

On the principles of hydrodynamically driven microfluidics

Master thesis (2024) - B. Bloemendaal, D.S.W. Tam, M.K. Ghatkesar
This study presents the development of a pro grammable microfluidic device designed for precise hydrodynamic manipulation of particles and fluids. Utilising femtosecond laser ablation and cold oxygen plasma bonding, the device features highly accurate microfluidic inlets with minimal surface rough ness, ensuring consistent flow dynamics. Experimental validation confirmed the device’s ability to generate uniform flow fields and half Rankine bodies, demonstrating its potential for real time reconfigurability in various applications, including particle manipulation and flow field analysis. The research lays the groundwork for future advancements in microfluidic technology, emphasising high precision and structural integrity. ...
Organ-on-chip (OoC) technology has transformed biomedical research by providing a platform to simulate physiological conditions for drug development and disease modeling. Incubator-free OoC systems offer notable advantages over traditional approaches, including enhanced adaptability and impermeability to gases. Nevertheless, achieving precise oxygen regulation remains a challenge in such systems. This thesis investigates the application of femtosecond (Fs) laser ablation to fabricate a glass microfluidic gas exchange system for accurate oxygen regulation in incubator-free OoCs.
Through successful engraving of fluidic channels and integration of an off-the-shelf optical oxygen sensor, this study highlights the efficacy of Fs laser technology in the rapid prototyping of intricate glass microfluidic devices. Despite encountering challenges such as dimensional losses and debris clogging, the study presents a functional gas exchanger prototype. Future research directions include optimization efforts, addressing issues like gas permeation through connectors, and testing under physiological conditions to further advance OoC technology. ...
When designing mechanical components, they commonly undergo multiple modeling phases for stress determination using analytical or numerical methods like the Finite Element Method (FEM). This is followed by experimental validation performed via stress mapping to identify and account for possible mechanical failure within the design phase. Among the experimental stress mapping techniques, mechanosensing is gaining rapidly increasing attention by research and industry. Mechanosensing is a chemistry-based technique that utilizes molecules called mechanophores. When mechanophores are embedded in transparent polymers, they act as mechanical probes sensing stress/strain throughout the polymer by emitting fluorescence under deformation. While studies have shown the capabilities of mechanophores as stress/strain probes qualitatively, it is currently not known how the mechanophore activation is correlated with the stress/strain-based quantities from a solid mechanics perspective. This study addresses this problem from a phenomenological viewpoint to fill the research area gap. In this work, using a uniaxial tensile testor, experiments are conducted on a Polydimethylsiloxane (PDMS) with a mechanophore spiropyran embedded homogeneously in the bulk of the polymer. The fluorescence data captured in the tests is correlated with the numerically obtained continuum mechanics stress/strain quantities. These correlations will be useful in giving directions towards research in the fundamental understanding of the mechanics of mechanophores, thereby bridging the gap between chemistry and mechanics of mechanosensors. This will pave the way towards optical-only in-situ measurements of stress-strain behavior. ...
Master thesis (2024) - M.A. Matzdorf, M.K. Ghatkesar, Vijayendra Shastri, M.E. Aubin-Tam
This study investigates the processes of cell membrane puncturing and the factors influencing these processes through force spectroscopy experiments. A custom-designed tall and sharp tip was fabricated on a commercially available microcantilever using two-photon polymerization (2PP). Force spectroscopy curves were measured at several locations on the cell while the tip was inserted inside the cell. A cell membrane insertion event, identified as a ”force drop” in force spectroscopy curves, is often hardly visible or does not occur. In this study, the effects of probe tip diameter, cantilever spring constant, insertion velocity, and cell height of mouse preosteoblast cells were systematically analysed for their influence on how often the force drops occur and how clearly they are visible. Data processing algorithms were employed to process thousands of force spectroscopy curves, enabling large sample statistical analysis using multiple linear regression. The results demonstrate that selecting cells with maximum height and size increases force drop occurrence from 10% to 40%. Furthermore, while decreasing the tip diameter from 2 to 0.7 µm did not affect the occurrence rate, it increased force drop visibility from ∼250 to ∼600 pico-Newton (pN). Additionally, cantilevers with a spring constant of 0.2 N/m achieved higher force drop occurrence (40%) and visibility (∼300 pN), compared to more flexible cantilevers with a spring constant of 0.02 N/m (20% occurrence, ∼40 pN visibility). These findings provide valuable insights for optimizing experimental parameters in cell membrane mechanics research. ...
Master thesis (2024) - T.M.L.M. Nguyen, M.K. Ghatkesar, Vijayendra Shastri, P. Boukany
Cancer metastasis, the spread of cancer cells from a primary tumor to distant organs, is the leading cause of cancer-related deaths. During metastasis, cancer cells undergo significant changes in their mechanical properties, including alterations in cell elasticity. Cancer cells generally exhibit higher elasticity than normal cells, a key feature that may contribute to their ability to migrate and invade other tissues. Although extensive research has focused on cell-substrate interactions, these studies do not fully replicate the physiological environment, where cells are frequently in direct contact with each other. In this study, Atomic Force Microscopy (AFM) in force spectroscopy mode, utilizing a micro-sized cantilever with a hemispherical tip, was used to quantify the Young’s modulus (E) of MCF-7 breast cancer cells in two configurations: cell-substrate and cell-cell. The resulting force-indentation curves were analyzed and fitted to the Hertz contact model to determine the Young’s modulus. The results showed that the Young’s modulus in the cell-cell configuration was Ecc = 205.8 ± 50.88 Pa, while in the cell-substrate configuration, it was Ecs = 187.95 ± 78.26 Pa. These findings suggest that MCF-7 cells are slightly less elastic in the cell-cell configuration. This challenges the expectation of a more significant difference between the two configurations and highlights the importance of considering biological variability and experimental conditions when interpreting cell mechanical properties. ...
Master thesis (2024) - X. WANG, M.K. Ghatkesar, T. Manzaneque Garcia, V. Ruiz Diez, Z. Wang, V. Giagka
Micropumps are essential for providing controlled fluid dynamics in Organ-on-a-Chip (OoC) devices. Additive manufacturing builds up prototypes in several hours with a free-geometry advantage. Therefore, this master's thesis investigates the utilization of additive manufacturing to produce a micropump with a flowrate in the range of several $\mu l/min$ for OoC applications. A ball valve-based piezoelectric micropump was fabricated with a mSLA 3D printer. This micropump generates unidirectional flow through the reciprocating motion of the piezoelectric actuator and the movement of a ball within the conical channel. The virtual mass due to the inertia of the fluid inside the chamber shifts the resonance frequency of the piezoelectric actuator from the 1600 Hz to 43 Hz. The maximum flow rate of $26.5 \mu l/min$ was generated when the applied sinusoidal voltage was 240 Vpp at 5Hz and the maximum back pressure of 36.5 mbar was obtained under this power supply. These results confirm that additive manufacturing provides a promising option for miniature pump manufacturing. ...
Photonics biosensors convert biomolecular interactions into quantifiable optical signals for biomedical analysis, which enable continuous monitoring of health indicators. Among them the microring resonator has a good sensing performance and a very broad application prospect. This thesis studies sensing with microfluidic integrated microring resonator photonic microchips.
This thesis adopts finite element method to simulate the optical behavior of waveguides and reactions in the microfluidic channel. The microfluidic channel was designed and prepared and then integrated to the photonic chip. The optical performance parameters of the micro ring resonator were tested by using a high-precision optical test system. The sensing performance of waveguide microring was studied using different aqueous solution as the detection object. The feasibility and effectiveness of the optical waveguide chip sensing have been preliminary verified.

...
Master thesis (2023) - V. Leshko, M.K. Ghatkesar, M. Mastrangeli
A stage heater for inverted optical microscopy was developed as an add-on to TU Delft portable integrated microfluidic platform. The platform was modified to gain additional functionality and portability. The stage heater was designed to work with custom PDMS microfluidic chips and commercial polymer chips which highlights the adaptability of the setup. The on-off temperature control was evaluated via an external thermocouple sensor, and the standard deviation of temperature in the cell chamber did not exceed 0.3 °C. An intermittent flow mode (flow for 1 minute at 10 µl/min, pause for 10 minutes) was introduced to match the requirements of an experiment involving T-cell and tumour spheroid interaction. The stage heater was deemed compatible with fluorescent and transmission imaging modes for up to 20x magnifications when equipped with a PET ITO-coated bottom heater with a window underneath the cell chamber. An increase in T-cell activity was observed with enabled heating. The process of T-cells attacking a spheroid via a time series of images was captured. ...
Master thesis (2023) - G. van der Gugten, M.K. Ghatkesar, V.U. Shastri, F. Linke, W. van Weerden, P. Boukany
Much research is conducted on the biomechanical properties of cells, particularly in cancer research. Cell stiffness and cell adhesion are two properties often studied, because they are important for the functioning of a cell. To study these properties, atomic force microscopy(AFM) is often used, using nanoindentation for stiffness analysis and fluid force microscopy(FluidFM) for adhesion analysis. However, these techniques often involve different cantilever probes, which complicates the measurement of both properties in a single cell. To make it possible to study cell stiffness and cell adhesion of a single cell, a multifunctional microfluidic AFM cantilever is developed in this research. This cantilever is equipped with a blunted pyramid-shaped tip for nanoindentation enabling the measurement of cell stiffness and imaging. Moreover, it features a channel running through its length, with an aperture on the tip, facilitating fluid force microscopy for determining cell adhesion. The multifunctional cantilever is fabricated using a multiscale 3d-printing technique, where stereo lithography is used for the larger parts, and two-photon polymerisation is used for the cantilever. To demonstrate the capabilities of the cantilever, tests are conducted on various substrates. Nanoindentation is demonstrated on PDMS, hydrogel and endothelial cells to determine the Young’s modulus of these materials. Fluid force microscopy is showcased by examining prostate cancer cells (PCA-3), removing the cells from the substrate while measuring the adhesion forces. The imaging capabilities of the cantilever were also demonstrated by generating a height map and a Young’s modulus map through quantitative imaging of a hydrogel spheroid. This research shows that combining the properties of nanoindentation and FluidFM cantilevers into a single cantilever is possible. Integrating these functionalities into a single cantilever makes doing more mechanical measurements on a single cell possible. ...
Master thesis (2023) - R. Smits, N. Bhattacharya, M.K. Ghatkesar, H. Kooiman
Single photon detectors are an important optical sensing tool in many industries. However, these highly efficient detectors suffer from variations in the size of an optical cavity when cooling down to 3K. An active positioning system is therefore required to correct the relative position of the fibre to the detector, so an optimal and reproducible cavity size can be achieved, thereby maximizing their efficiency. The literature study performed on cryogenic precision actuators showed that a stepper motor in combination with a motion reduction mechanism is the most feasible design. A stepper motor and a precision screw were two fundamental components of the preliminary design, so their lubrication was removed and were proven to work cryogenically. The rest of the design was based around these fundamental components. Room temperature tests were done to show the functionality of the design and it showed a positioning resolution between 10 nm and 30nm with just a 100nm loss of motion when unloading and loading the system. Cryogenic tests achieved similar results and it showed that the reflected power of a detector was reduced from 8.8% to 3.6%, indicating that the maximum achievable detector efficiency increased from 91.2% to 96.4%. ...
Master thesis (2023) - S.A.M. Elhassan, M.K. Ghatkesar, G. Özkayar
An Organ-on-a-Chip (OoC) is a microfluidic device that mimics an organ function on a chip. The goal of the OoC technology is to create disease models of various organs and use them to minimise animal testing. One of the important parameters to maintain the cells/tissues on the OoC is the temperature, typically at 37 °C. Usually, cell culture incubators are used to maintain the temperature of cells on the OoC. However, it is inconvenient for external flow control instrumentation to interface with OoC inside the incubator, and other temperatures being not possible. Therefore, an on-chip temperature controller is needed. In this report, a temperature control system for an OoC is designed, implemented and tested. To cover a wide temperature range, multiple peltier elements are chosen to confine the temperature control only at the region close to cell chambers in the OoC. A resistive temperature detector (RTD) is used as feedback to control the temperature by a proportional-integral-derivative (PID) controller. To avoid any heat loss beyond the Organ-on-a-Chip, a 3D-printed polylactic acid (PLA) holder with good thermal insulating properties is used. The holder is designed for four chips to accommodate control chips along with test chips. A dedicated PCB with control electronics is designed and implemented to control the temperature on all four chips powered by a battery. A temperature uniformity of +/- 0.7 °C of 19 mm at 68 μL/min and 23 mm at 10 μL/min along a total microfluidic channel length of 40 mm (from inlet to outlet), a width of 5 mm, and a depth of 0.3 mm before compression, was achieved. The response time to recover from changes in the temperature is approximately 2 minutes. With a power consumption of 0.84 Watts per chip to maintain 37 °C, four chips can function on a 20000 mAh battery for a minimum of 4.5 hours (only cooling at a minimum of 18 °C) and a maximum of 8.3 hours (only heating at 37 °C) before recharge. The temperature control system was tested on Hepatocytes and Cholangiocytes for liver-on-a-chip applications, which showed that the oxygen disappearance rate is 9.87 times faster when maintained at 37 °C compared to room temperature. ...
Microvalves are useful components for several microfluidic applications in which they control the fluid flow in a microfluidic system. Most microvalves to date are made by using silicon micro-machining, which is a complex manufacturing process, or soft lithography using Polydimethylsiloxane (PDMS) which has a high gas permeability. Next to that most microvalves in literature have small actuation forces resulting in small pressure ranges and large leakages at low pressure levels. In this paper, a normally open microvalve which is fabricated by only using 3D printing techniques with a bio-compatible resin is presented, making it more easy and accessible to manufacture. The novelty is the integrated micro-channels, membrane and microfluidic connections in a single 3D printed piece. The utilized actuator is a commercially available piezo stack, which has a displacement of 34 µm at 150V. Due to its large actuation force the microvalve can modulate fluids from -600 to 600 mbar, with measured flow-rate levels between 0-90 µl/min and projected flow-rate levels between 0-410 µl/min. In fully closed state the leakage-rate of the microvalve is 1.67 µl/min at 600 mbar, with a static power consumption of 442.5 mW. Subsequently it is shown that after using higher clamping torques (> 0.7 Nm) the microvalve can operate leakage free up to 1.5 bar. Additionally a 3-to-1 fluid selector is designed using three microvalves, which can be integrated into a portable microfluidic platform for Organ-on-Chip (OoC) applications. ...