This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) designed for 3-D ultrasonic imaging of the carotid artery. This application calls for an array of thousands of ultrasonic transducer elements, far exceeding the number of channels of conventional imaging systems. The 3.6 x 6.8 mm² ASIC interfaces a piezo-electric transducer (PZT) array of 24 x 40 elements, directly integrated on top of the ASIC, to an imaging system using only 24 transmit and receive channels. Multiple ASICs can be tiled together to form an even bigger array. The ASIC, implemented in a 0.18 μm high-voltage (HV) BCD process, consists of a reconfigurable switch matrix and row-level receive circuits. Each element is associated with a compact bootstrapped HV transmit switch, an isolation switch for the receive circuits and programmable logic that enables a variety of imaging modes. Electrical and acoustic experiments successfully demonstrate the functionality of the ASIC. In addition, the ASIC has been successfully used in a 3-D imaging experiment.
Accurate assessment of carotid artery disease by measuring blood flow, plaque deformation and pulse wave velocity using ultrasound (US) imaging requires 3D information. Additionally, the volume rates should be high enough (> 1 kHz) to capture the full range of these fast transient phenomena. For this purpose, we have built a programmable, tileable matrix array that is capable of providing 3D US imaging at such volume rates. This array contains an application-specific integrated circuit (ASIC) right beneath the acoustic piezo-stack (see Fig. 1a). The ASIC enables fast programmable switching between various configurations of elements connected to the acquisition system. This design also allows for expanding the footprint by tiling several of these arrays together into one large array. We explain the working principles and show the first basic imaging results of a single matrix array.
high-voltage 0.18 μm BCDMOS process, that interfaces a piezo-electric transducer array of 24 × 40 elements, directly integrated on top of the ASIC, to an imaging system using only 24 transmit and receive channels by means of a reconfigurable switch matrix and row-level low-noise amplifiers. Each element is associated with a compact bootstrapped high-voltage transmit/receive switch and programmable logic that enables a variety of imaging modes to be realized. The ASIC has been successfully used in a 3D imaging experiment. ...
high-voltage 0.18 μm BCDMOS process, that interfaces a piezo-electric transducer array of 24 × 40 elements, directly integrated on top of the ASIC, to an imaging system using only 24 transmit and receive channels by means of a reconfigurable switch matrix and row-level low-noise amplifiers. Each element is associated with a compact bootstrapped high-voltage transmit/receive switch and programmable logic that enables a variety of imaging modes to be realized. The ASIC has been successfully used in a 3D imaging experiment.
Accurate assessment of carotid artery disease by measuring blood flow, plaque deformation and pulse wave velocity using ultrasound imaging requires 3D information. Additionally, the volume rates should be high enough (> 1 kHz) to capture the full range of these fast transient phenomena. For this purpose, we have built a programmable, tileable matrix array that is capable of providing 3D ultrasound imaging at such volume rates. This array contains an application-specific integrated circuit (ASIC) right beneath the acoustic piezo-stack. The ASIC enables fast programmable switching between various configurations of elements connected to the acquisition system via a number of channels far smaller than the number of transducer elements. This design also allows for expanding the footprint by tiling several of these arrays together into one large array. We explain the working principles and show the first basic imaging results of a 2-by-1 tiled array.