A.C. Boerstra
Please Note
57 records found
1
Mandating indoor air quality for public buildings
If some countries lead by example, standards may increasingly become normalized
Throughout history, the human population has experienced major outbreaks of infectious diseases. In December 2019 the previously unknown SARS-CoV-2 virus emerged, which had a huge impact globally. Residents of long- term care facilities (LTCFs) showed to be highly susceptible to infection due to their frailty. Respiratory infectious diseases, such as COVID-19, can spread among others via the airborne transmission route. This is caused by sharing the same indoor environment. To reduce the risk of infection via the airborne route, it is important to consider ventilation and other building services system measures, including personalized ventilation (PV). PV has the potential of being a suitable solution for LTCFs, as it could still allow interaction between residents and visitors in the common rooms, which is regarded very important from a mental health perspective. To identify the potential of PV in the context of infection risk, a laboratory experiment was conducted to investigate its effectiveness on the infection risk reduction. The research was performed in a controlled climate chamber. In the experiment a person was mimicked and positioned close to a PV system that provided filtered recirculated air. A particle source maintained a constant particle concentration in the room. The performance of the PV system was measured through the particle concentration near the breathing zone as compared to the room concentration. Several design parameters were investigated. Translating the outcomes to a fictive (equivalent) ventilation rate, the Wells-Riley equation was applied to determine the infection risk. The outcomes indicated that, in this laboratory setting, the PV system can reduce the risk of an infection up to 50%. The performance is affected by the distance of the supply head to the breathing zone, the angle of the supply head, airflows in the room and the location of the particle source. To further optimize the system and allow its application in LTCFs, several aspects still need further attention, such as mobility/placing the person, the breathing pattern of the user and factors influencing the comfort and use.
Effectiveness of window signalling systems in open-plan workplaces
Evidence from field work
A new design method is proposed to calculate outdoor air ventilation rates to control respiratory infection risk in indoor spaces. We propose to use this method in future ventilation standards to complement existing ventilation criteria based on the perceived air quality and pollutant removal. The proposed method makes it possible to calculate the required ventilation rate at a given probability of infection and quanta emission rate. Present work used quanta emission rates for SARS-CoV-2 and consequently the method can be applied for other respiratory viruses with available quanta data. The method was applied to case studies representing typical rooms in public buildings. To reduce the probability of infection, the total airflow rate per infectious person revealed to be the most important parameter to reduce the infection risk. Category I ventilation rate prescribed in the EN 16798-1 standard satisfied many but not all type of spaces examined. The required ventilation rates started from about 80 L/s per room. Large variations between the results for the selected case studies made it impossible to provide a simple rule for estimating the required ventilation rates. Consequently, we conclude that to design rooms with a low infection risk the newly developed ventilation design method must be used.
During the 2020 COVID-19 pandemic, an outbreak occurred following attendance of a symptomatic index case at a weekly rehearsal on 10 March of the Skagit Valley Chorale (SVC). After that rehearsal, 53 members of the SVC among 61 in attendance were confirmed or strongly suspected to have contracted COVID-19 and two died. Transmission by the aerosol route is likely; it appears unlikely that either fomite or ballistic droplet transmission could explain a substantial fraction of the cases. It is vital to identify features of cases such as this to better understand the factors that promote superspreading events. Based on a conditional assumption that transmission during this outbreak was dominated by inhalation of respiratory aerosol generated by one index case, we use the available evidence to infer the emission rate of aerosol infectious quanta. We explore how the risk of infection would vary with several influential factors: ventilation rate, duration of event, and deposition onto surfaces. The results indicate a best-estimate emission rate of 970 ± 390 quanta/h. Infection risk would be reduced by a factor of two by increasing the aerosol loss rate to 5 h−1 and shortening the event duration from 2.5 to 1 h.
Exposure to increased concentrations of particulate matter (PM2.5) is related to a higher risk of respiratory and vascular diseases. Indoors, cooking appears to be a major source of PM2.5. In dwellings it has been demonstrated that cooking can lead to concentrations well above the health limits. However, only little is known about the concentrations typically observed in professional kitchens where cooking is the major activity. Therefore, an inventory field study has been set up to measure PM2.5 exposure in the breathing zone of chefs in professional restaurants. In total seven restaurants took part in the study. In all kitchens, PM2.5 exposure in the breathing zone of the chef and at two locations in the kitchen was measured. During the measurements activities of the chef were listed and characteristics of the kitchens were mapped (e.g. open/closed kitchen, type of ventilation, type of food that is prepared). The initial results show that in all restaurants, chefs are exposed to concentrations above the WHO-limit, i.e. average daily exposure of 25 µg/m3. Cooking style, hood and background concentration in the kitchen are factors contributing to the concentration in the kitchen. However, the peak exposure of the chef appears to be highly dependent on behavior and location in relation to the stove and exhaust hoods.
Virustransmissie bij covid-19
De rol van aerosolen
Technological progress in conditioning practice combined with prevailing thermal comfort criteria, created stable, tightly controlled indoor temperature bands. Research shows indoor temperatures to be increasing in the heating period, leading to higher building energy use than planned. Field studies provide proof that occupants not in control of their indoor climate are more dissatisfied and report problems in wellbeing. Widening temperature bands could be an effective measure leading to energy conservation, increasing satisfaction and, as shown recently, helping to mitigate health problems related to our way of life. The adaptive approach to thermal comfort postulates that people's thermal comfort perception adapts to the indoor and outdoor climatic conditions they normally experience. However, according to standards, the adaptive model is applicable only to passively conditioned (free-running) buildings, even though the adaptive principles may well apply also to actively conditioned buildings. Our review found studies demonstrating positive health effects and energy conservation potential in permanently or seasonally conditioned buildings. On this basis, the potential of the adaptive approach and translations into concrete design or operation solutions for actively conditioned buildings are discussed in this paper. We conclude that the adaptive concept offers a potential for indoor climate control in actively conditioned buildings in the temperate and cold climates.
Literature sets personal control over indoor environmental conditions in relation to the gap between predicted and actual energy use, the gap between predicted and observed user satisfaction, and health aspects. A focus on building energy performance often leads to the proposal of more automated and less occupant control of the indoor environment. However, a high degree of personal control is desirable because research shows that a low degree (or no) personal control highly correlates with indoor environmental dissatisfaction and sick building syndrome symptoms. These two tendencies seem contradictory and optimisation almost impossible. Based on current efficiency classes describing the effect of room automation systems on building energy use during operation, fundamental thoughts related to thermophysiology and control, recent laboratory experiments, important lessons learnt from post-occupancy studies, and documented conceptual frameworks on the level of control perceived, we discuss the ambivalence of personal control and how much personal control is adequate. Often-proposed solutions ranging from fully automated controls, over manual controls to dummy controls are discussed according to their effect on a) building energy use during operation and b) occupants perceived control. The discussion points to the importance of adequate personal control. In order to meet the goals for nearly zero energy buildings and for a human-centric design, there is the need to establish design procedures for adequate personal control as part of the design process.
In 2004 the first adaptive thermal comfort guideline was introduced in the Netherlands. Recently a new, upgraded version of this ISSO 74 (ATG) guideline has been developed. The new requirements are hybrid in nature as the 2014 version of the guideline combines elements of traditional non-adaptive comfort standards with elements of adaptive standards. This paper describes the new guideline and explains the rationale behind it. Also changes in comparison with the original 2004 version and issues related to performance verification are discussed. The information presented in this paper can be used by others (other countries) as inspiration material for other new adaptive comfort guidelines and standards.
Qualité de l'air intérieur et confort dans les espaces de bureaux, et relations avec la performance au travail
Volet français du projet OFFICAIR, Partie 2
The OFFICAIR project aimed to describe comfort and indoor air quality (IAQ) in new and retrofitted office buildings in Europe. In France, 21 office buildings participated in this project. In a subsample of five buildings, IAQ measurements and performance tests were carried out to study the relations between IAQ and work performance. Twenty-one compounds were measured (volatile organic compounds, aldehydes, nitrogen dioxide, and ozone) as well as environmental parameters: Carbon dioxide, temperature, and relative humidity, over five days in two different seasons. The occupants in the investigated rooms were invited to participate in two on-line task performance tests: A reaction time test, i.e., the standardized Deary-Liewald test, and a memory test. There were participants in summer and 98 in winter. They also provided self-assessments of the influence of the indoor environment on their productivity. The multilevel linear regression models showed that individual characteristics were the main factors determining performance at work. Indoor air concentrations of xylenes and ozone might influence reaction time during summer. Both in summer and winter, the occupants' satisfaction regarding noise and their perceived ability to control their indoor temperature increased their self-assessed productivity. This work is the first to study the influence of IAQ on performance in real work environments and on the basis of IAQmeasurements. This study was limited to five buildings, but it would be useful to repeat it on a larger scale.