C. Roda
Please Note
9 records found
1
Qualité de l'air intérieur et confort dans les espaces de bureaux, et relations avec la performance au travail
Volet français du projet OFFICAIR, Partie 2
The OFFICAIR project aimed to describe comfort and indoor air quality (IAQ) in new and retrofitted office buildings in Europe. In France, 21 office buildings participated in this project. In a subsample of five buildings, IAQ measurements and performance tests were carried out to study the relations between IAQ and work performance. Twenty-one compounds were measured (volatile organic compounds, aldehydes, nitrogen dioxide, and ozone) as well as environmental parameters: Carbon dioxide, temperature, and relative humidity, over five days in two different seasons. The occupants in the investigated rooms were invited to participate in two on-line task performance tests: A reaction time test, i.e., the standardized Deary-Liewald test, and a memory test. There were participants in summer and 98 in winter. They also provided self-assessments of the influence of the indoor environment on their productivity. The multilevel linear regression models showed that individual characteristics were the main factors determining performance at work. Indoor air concentrations of xylenes and ozone might influence reaction time during summer. Both in summer and winter, the occupants' satisfaction regarding noise and their perceived ability to control their indoor temperature increased their self-assessed productivity. This work is the first to study the influence of IAQ on performance in real work environments and on the basis of IAQmeasurements. This study was limited to five buildings, but it would be useful to repeat it on a larger scale.
Rhinitis bij Nederlandse studenten
Wordt rhinitis beïnvloed door de woonomgeving van studenten?
Perception de la qualité de l'air intérieur, du confort et de la santé dans les espaces de bureaux, et relations avec les caractéristiques techniques des bâtiments
Volet français du projet OFFICAIR, Partie 1
The OFFICAIR project aimed to describe comfort and indoor air quality in new and retrofitted office buildings in Europe. This article reports the perceived comfort and health, as well as their relations with building characteristics, in the 21 participating office buildings in France. Occupant perception and personal information were collected through an online questionnaire. In parallel, a building audit was performed to describe each building. The survey took place between January and April 2012 over two weeks in each building. Among the 1,190 respondents, 54% were dissatisfied with the noise from the other occupants, 48% with dry air, and 46% with stuffy air. The most common health symptoms attributed to the building were headaches (31% of the respondents), dry eyes (27%), irritated eyes (21%) and a dry or sore throat (21%). No difference was observed between the French buildings and the European sample (167 buildings, 7,441 respondents). The perceived indoor environment and related health symptoms seemed similar to those reported in past studies. The multilevel linear regressions highlight the major influence of the individual parameters on both indoor air quality and comfort perception, as well as on PSI-5 (number of building-related symptoms across five symptoms defining the sick building syndrome). Occupants who could control their indoor environment had better perceptions. Similarly, an efficient procedure for managing building-related complaints was associated with better perceptions of indoor air quality and comfort and with fewer building-related health effects.
workers’ comfort, and consequently their health and well-being, as well as their productivity.
This study aimed to assess the relations between perceived indoor environment and occupants’
comfort, and to examine the modifying effects of both personal and building characteristics.
Within the framework of the European project OFFICAIR, a questionnaire survey was administered to
7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece,
Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental
quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor
air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold
temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office
environment. Ordinal logistic regression analyses were performed to assess the relations between
perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was
found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed
parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall
comfort. “Layout of the offices” was the next parameter highly associated with overall comfort.
The relations between IEQ and comfort differed by personal characteristics (gender, age, and the
Effort Reward Imbalance index), and building characteristics (office type and building’s location).
Workplace design should take into account both occupant and the building characteristics in order to
provide healthier and more comfortable conditions to their occupants. ...
workers’ comfort, and consequently their health and well-being, as well as their productivity.
This study aimed to assess the relations between perceived indoor environment and occupants’
comfort, and to examine the modifying effects of both personal and building characteristics.
Within the framework of the European project OFFICAIR, a questionnaire survey was administered to
7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece,
Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental
quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor
air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold
temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office
environment. Ordinal logistic regression analyses were performed to assess the relations between
perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was
found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed
parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall
comfort. “Layout of the offices” was the next parameter highly associated with overall comfort.
The relations between IEQ and comfort differed by personal characteristics (gender, age, and the
Effort Reward Imbalance index), and building characteristics (office type and building’s location).
Workplace design should take into account both occupant and the building characteristics in order to
provide healthier and more comfortable conditions to their occupants.
Office characteristics and dry eye complaints in European workers
The OFFICAIR study
Self-reported health and comfort in student homes
First results from a survey among students from different universities in the Netherlands
While the indoor environmental quality of student homes is a potential issue since it may affect the wellbeing of the students, the relations are still poorly studied. This study aimed to investigate the relations between home building characteristics and rhinitis in students.
Material and methods
A questionnaire was distributed among four groups of students from three different universities in The Netherlands. Self-reported characteristics of 396 students and their homes were linked to self-reported rhinitis. Logistic regression modelling was applied to explore relations between building characteristics and rhinitis.
Results
Among the students studied, 33% declared to suffer from rhinitis in the last 12 months. After full adjustment, the regression model revealed that having relatives with rhinitis was positively associated with rhinitis (OR:5.27, CI: 3.02–9.21) as well as the presence of less than one-year old furniture made of MDF in the bedroom (OR:2.26, CI: 1.17–4.37). Both working out and having no pets was negatively linked to rhinitis (respectively OR:0.50, CI: 0.25–0.99 and OR: 0.37, CI: 0.18–0.74). Opening the window in the bedroom more than once a week also reduced the risk for rhinitis (OR: 0.55, CI: 0.31–0.98).
Conclusions
The study shows that biological pollutants (caused by pets), chemical pollutants (caused by MDF in bedroom), ventilation (opening window in bedroom) and workout, were associated with rhinitis in students. Further studies are needed to investigate the underlying causes to prevent rhinitis in young adults. ...
While the indoor environmental quality of student homes is a potential issue since it may affect the wellbeing of the students, the relations are still poorly studied. This study aimed to investigate the relations between home building characteristics and rhinitis in students.
Material and methods
A questionnaire was distributed among four groups of students from three different universities in The Netherlands. Self-reported characteristics of 396 students and their homes were linked to self-reported rhinitis. Logistic regression modelling was applied to explore relations between building characteristics and rhinitis.
Results
Among the students studied, 33% declared to suffer from rhinitis in the last 12 months. After full adjustment, the regression model revealed that having relatives with rhinitis was positively associated with rhinitis (OR:5.27, CI: 3.02–9.21) as well as the presence of less than one-year old furniture made of MDF in the bedroom (OR:2.26, CI: 1.17–4.37). Both working out and having no pets was negatively linked to rhinitis (respectively OR:0.50, CI: 0.25–0.99 and OR: 0.37, CI: 0.18–0.74). Opening the window in the bedroom more than once a week also reduced the risk for rhinitis (OR: 0.55, CI: 0.31–0.98).
Conclusions
The study shows that biological pollutants (caused by pets), chemical pollutants (caused by MDF in bedroom), ventilation (opening window in bedroom) and workout, were associated with rhinitis in students. Further studies are needed to investigate the underlying causes to prevent rhinitis in young adults.