Objective: Navigation through tortuous and deformable vessels using catheters with limited steering capability underscores the need for reliable path planning. State-of-the-art path planners do not fully account for the deformable nature of the environment. Methods: This work pro
...
Endovascular intervention is a minimally invasive method for treating cardiovascular diseases. Although fluoroscopy, known for real-time catheter visualization, is commonly used, it exposes patients and physicians to ionizing radiation and lacks depth perception due to its 2D nat
...
Diffuse Reflectance Spectroscopy (DRS) can provide tissue feedback for pedicle screw placement in spine surgery, yet the integration of fiber optics into the tip of the pedicle probe, a device used to pierce through bone, is challenging, since the optical probing depth and signal
...
BACKGROUND AND PURPOSE: Although MRI-based image guided adaptive brachytherapy (IGABT) for locally advanced cervical cancer (LACC) has resulted in favorable outcomes, it can be logistically complex and time consuming compared to 2D image-based brachytherapy, and both physically a
...
Enhancing Intraoperative Tissue Identification
Investigating a Smart Electrosurgical Knife's Functionality During Electrosurgery
Objective: Detecting the cancerous growth margin and achieving a negative margin is one of the challenges that surgeons face during cancer procedures. A smart electrosurgical knife with integrated optical fibers has been designed previously to enable real-time use of diffuse refl
...
Background: Compliance with the recommended 30 s drying time of alcohol-based hand rub (ABHR) is often suboptimal. To increase hand hygiene compliance at a neonatal intensive care unit (NICU), we installed an Incubator Traffic Light (ITL) system which shows ‘green light’ to open
...
The SATA-Drive
A Modular Robotic Drive for Reusable Steerable Laparoscopic Instruments
Introduction: Most robotic instruments and their drives still risk residual contamination due to cleaning complexities, rendering them limited reusable, and tend to have larger instruments than the 5mm laparoscopic standard. The novel steerable laparoscopic SATA-LRS uses modulari
...
Objective: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the dista
...
A review on machine learning in flexible surgical and interventional robots
Where we are and where we are going
Minimally Invasive Procedures (MIPs) emerged as an alternative to more invasive surgical approaches, offering patient benefits such as smaller incisions, less pain, and shorter hospital stay. In one class of MIPs, where natural body lumens or small incisions are used to access de
...
Seeing from a new angle
Design of a sideways-looking fiber-optic probe to advance spine surgery
Our research highlights the potential of Diffuse Reflectance Spectroscopy (DRS) in detecting cortical breaches during pedicle screw placement. We propose a sideways-looking fiber-optic probe, integrating diffuse light emission with both forward and sideways light collection. Expe
...
Objectives
To study the methodology and results of studies assessing the relationship between fetal heart rate and specified neonatal outcomes including, heart rate, infection, necrotizing enterocolitis, intraventricular hemorrhage, hypoxic-ischemic encephalopathy, and seizur ...
To study the methodology and results of studies assessing the relationship between fetal heart rate and specified neonatal outcomes including, heart rate, infection, necrotizing enterocolitis, intraventricular hemorrhage, hypoxic-ischemic encephalopathy, and seizur ...
Annually, over 300 million surgeries occur globally, requiring numerous surgical instruments. However, many instruments on the tray are returned to the central sterile supply department (CSSD) unused, creating an unsustainable pattern of unnecessary consumption. To address this,
...
Collision feedback about instrument and environment interaction is often lacking in robotic surgery training devices. The PoLaRS virtual reality simulator is a newly developed desk trainer that overcomes drawbacks of existing robot trainers for advanced laparoscopy. This study ai
...
It is estimated that in Africa 30,000-130,000 new cases arise annually and a total of 3 million women suffer from untreated vesicovaginal fistulas (VVFs) in Low- and Middle-Income Countries (LMICs) worldwide. A VVF is an abnormal communication between the bladder and vagina that
...
Endovascular interventions are minimally invasive procedures that utilize the vascular system to access anatomical regions deep within the body. Image-guided assistance provides valuable real-time information about the dynamic state of the vascular environment. However, the relia
...
Manipulating a flexible ureteroscope is difficult, due to its bendable body and hand–eye coordination problems, especially when exploring the lower pole of the kidney. Though robotic interventions have been adopted in various clinical scenarios, they are rarely used in ureterosco
...
Background: The steep radiation dose gradients in cervical cancer brachytherapy (BT) necessitate a thorough understanding of the behavior of afterloader source cables or needles in the curved channels of (patient-tailored) applicators. Purpose: The purpose of this study is to dev
...
Six smart guidelines for high-tech manufacture on low-tech 3D printers
The case of the 3Flex
While articulated surgical instruments have enabled the proliferation of minimally invasive interventions, procedures such as laparo-endoscopic single-site surgery are waning in popularity. One potential reason for this decline is a lack of sufficiently dexterous instruments. Alt
...
Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leadin
...
Introduction: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suita
...