DG

Davide Gulotta

3 records found

Salt crystallization is a major cause of damage in porous building materials. Accelerated salt weathering tests carried out in the laboratory are among the most common methods to assess the durability of material to salt decay. However, existing standards and recommendations for ...
The RILEM TC ASC-271 is developing a new laboratory test to assess the durability of porous building materials to salt crystallisation. The test encompasses two phases: salt accumulation and damage propagation. This paper focuses on designing a procedure for the accumulation phas ...

Recommendation of RILEM TC 243-SGM

Functional requirements for surface repair mortars for historic buildings

Surface repair mortars are used for the compensation, or repair, of lost portions of surface materials in historic masonry buildings. It is recommended that their design and application should be performed in a wider context of conservation values related decision making, to prio ...