Evaluation of a Low-Latency, High-Accuracy Intrusion Prevention System for Digital Substations

Conference Paper (2026)
Author(s)

N. Cibin (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Marijn Boringa (Student TU Delft)

I. Semertzis (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Alex Stefanov (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Research Group
Intelligent Electrical Power Grids
DOI related publication
https://doi.org/10.1109/PESGM58988.2026.11693451 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Intelligent Electrical Power Grids
Publisher
IEEE
ISBN (print)
979-8-3315-8139-8
ISBN (electronic)
979-8-3315-8138-1
Event
2026 IEEE Power & Energy Society General Meeting (PESGM) (2026-07-19 - 2026-07-23), Montreal, Canada
Page Views
55
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

The increasing digitalization of the power grid and widespread adoption of the IEC 61850 standard have raised concerns regarding the cyber security of electrical substations. In particular, the Sampled Values (SV) protocol lacks inherent security mechanisms, leaving protection and control functions vulnerable to malicious SV frames injection. To address this challenge, a method using hybrid statistical-deep learning was previously proposed to detect, prevent, and localize SV injection attacks in digital substations, while ensuring minimal latency and near-zero false positives. In this work, we evaluate and experimentally validate the real-time implementation of the proposed Intrusion Prevention System (IPS) using a hardware-in-the-loop testbed consisting of a Real-Time Digital Simulator (RTDS), Raspberry Pi implementing the intrusion prevention method, and an industrial intelligent electronic device. Multiple operating scenarios are considered to evaluate fault clearance latency, communication reliability, IPS classification performance, and IPS impact on protection schemes. Results demonstrate that the IPS introduces less than 150 μs of additional delay, achieves a near-zero false positive rate in the absence of cyber attacks, and attains an F1-score above 99% in preventing SV injection attacks, while preserving substation protection and control functionalities. These findings confirm the practicality and effectiveness of the proposed IPS for deployment in IEC 61850-compliant digital substations.