ED
EH Durr
13 records found
1
Array of pluvio meters. Meaning of data unclear (?)@en
Code: GRW 21
Type: Temperature and Pressure sensor
Make: Keller DCX-22 AA
This instrument is based on differential pressure measurement of two absolute sensors.
The sensors measure pressure and temperature.
Height of piezometer above sensor: 1.18m.@en
Type: Casella Tipping Bucket 100000 E
This instrument measures rainfall by counting the times a bucket tips over
due to filling with rainfall.
Aperture 400 cm3 (?)
Bucket size 0.2mm (?)@en
Type: Pressure Sensor Keller DCX-4.0, SN 1467
This instrument is based on differential pressure measurement of two
absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: -0.0015m.
Datasets with correction contain the corrected discharge ob
...
Type: Pressure Sensor Keller DCX-4.0, SN 1466
This instrument is based on differential pressure measurement of two
absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: -0.017m.@en
Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-h
...
Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-h
...
According to original data the location is Westerbork NL but this is probably wrong Evaporation measument.
Area basin 1.00 m2, 2x3 strain gauges: type FLA-6, resistance 120 Ohm.
Valve (<18 jan 2006): electronic magnetic valve Type: MBMG2Z-1263008-12V. (KOBOLD Instrumentatie BV, A
...
Surface area of the Attert basin at measurement station Useldange is 245 km2
The measurement station of Useldange in the Attert river (LU) is part of a wider hydro-climatological measurement network, encompassing the whole of the Grand Duchy of Luxembourg. Discharge data obtained
...
In 2004 Delft University of Technology has developed a forest floor interception measuring device.
It measures the evaporation from interception of the forest floor.
The device consists of a permeable upper basin filled with forest floor and a watertight lower basin that are weig
...