Journal article (2026) - Abdul Mohizin, Leon Abelmann, Baeckkyoung Sung
High-frequency electromagnetic fields (EMFs) are increasingly recognized either as environmental risk factors or as tools for electromagnetic attacks, which are difficult to detect in situ. Existing high-frequency EMF sensors face significant limitations related to structural simplicity, integration with mobile technology, and low energy consumption. To address these challenges, we propose a miniature sensor concept based on a magnetically hybridized liquid crystal (LC) microdevice. The hybrid LC chip is designed to exhibit an optical response to external radio-frequency fields without the need for electronic components or an external power supply, relying solely on ambient light. Both sides of the chip are covered with polymer-based crossed polarizer films. The chip is filled with flexible matrices containing thermotropic LCs, such as the rod-like 4-cyano-4′-pentylbiphenyl, into which a network of thin ferromagnetic wires is embedded. The resulting field-responsive LC microdisplay operates via a simple magnetothermal mechanism, and its optical response is sufficiently strong to be visible to the naked eye. ...
Journal article (2026) - E. Aprea, F. Pirim, F.S. Stallone, Vasiliki Gkouzioti, Zhengwei Liao, L. Abelmann, J.P. Frimat, Pasqualina M Sarro, Clementine Boutry
Fully biodegradable microsystems enable therapies for temporary medical conditions that could not be addressed before. We present the first entirely biodegradable, wireless, implantable micropump for biomedical applications, with potential uses ranging from internal negative pressure wound therapy and drug delivery to soft robotics for temporary incontinence. As a proof-of-concept, the micropump was designed for peripheral nerve repair. It is magnetically actuated, featuring a nozzle/diffuser configuration, with a membrane of POMaC elastomer bonded to a magnetic POMaC/CIP composite. POMaC/CIP 20 wt% is selected for its mechanical and magnetic properties (Young’s modulus: 45 kPa, magnetic relative permeability: 1.14). A magnetic disc (6 mm x 0.5 mm) maximizes displacement and is actuated via a motor-driven magnetic setup at 4-8 Hz. An equivalent circuit model predicts under-pressure generation trends, confirmed experimentally through continuous/alternate pumping, repeatability assessments, and 240,000-cycle stability tests. In vitro and ex-vivo tests demonstrate consistent under-pressure (~2.3 kPa), meeting nerve regeneration requirements. Accelerated degradation tests show 31% mass loss after seven weeks, supporting short-term use. This platform is adaptable to diverse biomedical contexts, enabling novel therapies previously unachievable. ...
Journal article (2026) - Indujan Sivanesarajah, Leon Abelmann, Uwe Hartmann
Thin-film giant magnetoimpedance (GMI) structures are promising candidates for high-frequency magnetic sensing, with their performance governed by the interplay of electronic transport, magnetic softness, and ferromagnetic resonance (FMR). Optimisation therefore requires a comprehensive understanding of the properties of soft magnetic materials. This study investigates the structural, electric, magnetic, and GMI properties of sputtered amorphous CoNbZr single layers, amorphous CoNbZr/Au multilayers, and crystalline NiFe/Au multilayers. GMI measurements reveal distinct FMR frequencies of 1.4 GHz (CoNbZr), 0.7 GHz (CoNbZr/Au), and 0.5 GHz (NiFe/Au). Introducing Au interlayers into CoNbZr lowers the FMR frequency by 50% and enhances the maximum GMI ratio by a comparable margin relative to the single-layer film. At 1.8 GHz, the highest GMI performance is observed in a 20μm×5000μm CoNbZr/Au strip, yielding 300% with a sensitivity of 249%/kAm−1. Under identical conditions, single-layer CoNbZr reaches 180% (169%/kAm−1) and NiFe/Au 280% (183%/kAm−1), confirming the superior response of the CoNbZr/Au multilayer. These improvements are attributed to differences in in-plane demagnetising factors and saturation magnetisations, providing design guidelines for the development of resonant GHz-range GMI sensors. ...
Journal article (2026) - Seongho Jeong, Ki Eun Kim, Chang Ho Han, Baeckkyoung Sung, Leon Abelmann
In response to emerging threats associated with natural disasters, environmental pollution, and infectious diseases, the detrimental influences of airborne aerosols on humans have been investigated at the cellular level. Especially, intensive efforts have been devoted to system automation in order to enhance the efficiency, precision, and machine intelligence of aerosol cytotoxicity analysis. In this context, we combine the concepts of small-size automated and robotic platforms used for monitoring the harmful effects of aerosols. A conceptual framework is provided with a focus on mobile and field-deployable platforms that enable automated operation of (bio-)engineered systems on-site. Particular attention is given to the principles of biomimetic device design and the underlying physical and engineering mechanisms, to provide a system-level estimation on the complete “source-to-effect” workflow. In view of workflow integration, additional emphasis is placed on data acquisition and processing, as well as the extension of these technologies to autonomous system-supported environmental health applications. ...
Journal article (2026) - Joost Wijnmaalen, Leon Abelmann, Iulian Apachitei
This study compares the propulsion of scaled-up helical microrobot models, based on hard- and soft-magnetic elements under rotating magnetic fields. The experiments were performed at the millimeter scale and interpreted using hydrodynamic scaling laws to predict microscale behavior. Results show that hard-magnetic microrobots achieved step-out frequencies and maximum propulsion speeds 4.5 times higher than soft-magnetic microrobots. Below saturation magnetization, soft-magnetic microrobots demonstrated similar performance irrespective of magnetic susceptibility, highlighting that torque generation in these materials is purely geometry-dependent. Employing a tapered ribbon design increased propulsion speed by a factor of 3.5 compared to regular helical designs. These results show that the impact of using soft rather than hard magnets is manageable, allowing for biodegradable magnets such as pure iron. The theory and experiments in this paper provide a quantitative basis for selecting materials and designs. ...
Journal article (2025) - Yao Junxiang, Maurits E.K. Geenen, Harm A. Bakker, Leon Abelmann, Jan Aarts
Creation and manipulation of magnetic domain walls (DWs) are a core subject of research in developing prototype devices for spintronic applications. DWs can be created artificially and moved by applying either a magnetic field or an electric current, as has been extensively investigated. Here, we study the DW pinning and depinning in half-metallic ferromagnetic La0.7Sr0.3MnO3 nanostructures with a notch that is about 90% of the width of the wire. By measuring the magnetoresistance of the notched wires while sweeping the magnetic field, we unambiguously observe DW pinning and depinning from 10 to 300 K. Analysis of the temperature dependence reveals that both ΔR (the DW resistance) and ΔR/R0 (R0 is the resistance at zero field) are proportional to the temperature. The DW resistivity is calculated to be of the order of 10−17Ωm2 at 10 K and 10−15Ωm2 at 300 K. The latter value agrees with the reported intrinsic DW resistivity in films. In addition, we find approximately constant ΔR and ΔR/R0 for widths from 1.8µm and a pronounced increase in both quantities when the width goes down to 755 nm. With the extracted magnetocrystalline anisotropy parameters from the measurements of the remanent magnetization and the magnetic torque as function of angle of the magnetic field with respect to the substrate normal, we further perform micromagnetic simulations and obtain results consistent with the experimental data. Our work may promote designing relevant prototypes and may constitute a platform to explore the effect of spin torque transfer on DWs. ...
Journal article (2025) - Indujan Sivanesarajah, Leon Abelmann, Uwe Hartmann
Amorphous sputtered Co-based thin films are widely used as soft magnetic materials in applications such as sensors, inductors and magnetic flux concentrators. The magnetic properties of these films can be controlled by deposition parameters like film thickness, argon pressure, deposition rate and others. In this study, we present a detailed investigation of the magnetic properties of RF-sputtered Co90Nb8Zr2 films with thicknesses ranging from 52 nm to 1040 nm. These amorphous films exhibit an average saturation magnetisation of (1.01 ± 0.04) MA/m. As the film thickness increases, there is a significant decrease in coercivity, remanent-to-saturation magnetisation ratio Mr/Ms, and maximum permeability. The change in macroscopic magnetic properties is also reflected by the domain structure. At a thickness of 52 nm, the remanent domain state shows irregular domains, while films thicknesses above 208 nm exhibit flux-closure domain structures instead. The thickness-dependent modifications are attributed to the transition between Néel and Bloch type domain walls, which is expected to occur at approximately 84 nm. ...
Peripheral Nerve Injury (PNI) leads to significant motor and sensory impairments, with limited recovery potential in injuries exceeding 3 cm, Conventional treatments often fail to achieve full functional restoration. Suction-based approaches at lesion sites have demonstrated promising outcomes in nerve regeneration. This work presents a novel wireless, magnetically actuated micropump composed of biodegradable materials, such as poly(octamethylene-maleate(anhydride)citrate) (POMaC), for nerve repair applications. The micropump integrates a magnetic ring within its membrane, enabling deflection under alternating magnetic field (4Hz,pm 150mT), generating a net under-pressure of 1.3 kPa within 8 minutes. It provides a potential solution to facilitate nerve healing. ...
Journal article (2025) - I. Castro, A. Riveros, J. L. Palma, L. Abelmann, R. Tomasello, D. R. Rodrigues, A. Giordano, G. Finocchio, R. A. Gallardo, N. Vidal-Silva
In this work, we explored theoretically the spatial resolution of magnetic solitons and the variations of their sizes when subjected to a magnetic force microscopy (MFM) measurement. Next to tip-sample separation, we considered reversal in the magnetization direction of the tip, showing that the magnetic soliton size measurement can be strongly affected by the magnetization direction of the tip. In addition to previous studies that only consider thermal fluctuations, we developed a theoretical method to obtain the minimum observable length of a magnetic soliton and its length variation due to the influence of the MFM tip by minimizing the soliton’s magnetic energy. We show that a simple spherical model for the MFM tip can capture most of the physics underlying tip-sample interactions, with the key requirement being an estimate of the magnetization field within the sample. Our model uses analytical and numerical calculations and prevents overestimating the characteristic length scales from MFM images. We compared our method with available data from MFM measurements of domain wall widths, and we performed micromagnetic simulations of a skyrmion-tip system, finding a good agreement for both attractive and repulsive domain wall profile signals and for the skyrmion diameter in the presence of the magnetic tip. In addition, the theoretically calculated frequency shift presents good qualitative agreement with experimental measurements. Our results provide significant insights for a better interpretation of MFM measurements of different magnetic solitons and will be helpful in the design of potential reading devices based on magnetic solitons as information carriers. ...
Journal article (2024) - Ngoc Quang Nguyen, Younhee Jeong, Leon Abelmann, Jungju Ryu, Daewon Sohn
Halloysite nanotubes (HNTs) have been extensively investigated for potential utilization due to their unique structure and properties as a type of natural, eco-friendly clay. The synthesis and modification of magnetic halloysite nanotubes was studied using several experimental techniques including SEM, TEM, FT-IR, Raman spectroscopy, UV-Vis spectroscopy, and BET. Dye absorption experiments were conducted to understand bonding using EDS, XPS, XRD, and Raman spectroscopy. In this study, we evaluated Sunset Yellow FCF (SY) dye removal as a model to understand bonding structures among magnetic HNTs, magnetic particles, and dye molecules. We focus on the interactions of SY-magnetic HNTs and characteristics of magnetization by VSM after SY dye adsorption, which highlight the notable features of magnetic halloysite nanotubes. We used different pH environments to study the behavior of magnetic HNTs after dye absorption. The application of these modified HNTs is promising for future organic dye removal and wastewater treatment. ...
Journal article (2023) - Veronika Magdanz, Anke Klingner, Leon Abelmann, Islam S.M. Khalil
Cell membrane potential affects the electrostatic self-assembly of magnetizable nanoparticles around the flagellum of sperm cells, leading to the formation of biohybrid microrobots (i.e., IRONSperm) with various bending stiffness. Here we explain the influence of bull sperm cell membrane potential on the formation of two types of IRONSperm samples that are produced by electrostatic self-assembly. The first type is a proximal-coated soft body with nanoparticles concentrated on the head to maintain high flexibility of the flagellum and create a passively propagating transverse bending wave under the influence of an external rotating magnetic field. The second type is a rigid-body with nanoparticles approximately uniformly distributed along the length to provide arbitrary geometry that maintains a constant chiral shape and propel by rotation about its long axis. We present a magneto-elastohydrodynamic model to predict the swimming speed at low Reynolds number for rigid IRONSperm with arbitrary shapes, and show that decreasing the bending stiffness allows the model to capture the behavior of its soft counterpart. While the response of a rigid chiral IRONSperm is distinguished by a greater swimming speed with a smooth decay with frequency, the benefit of a soft flagellum in certain scenarios would present a much smaller range of frequencies for wireless actuation. ...
Journal article (2023) - Sukhvinder Singh, Leon Abelmann, Haibin Gao, Uwe Hartmann
Well-defined and technically relevant domain configurations are sought in patterned magnetic thin films. We used Magnetic Force Microscopy to investigate these in square-patterned Permalloy films. The films were prepared using dc sputter deposition by varying the Argon pressure from 1.5×10−3 to 30.0×10−3 mbar. The Landau domain configuration was found in films prepared at 1.5×10−3 mbar pressure. With an increase in pressure, tulip and irregular domains were consecutively formed. Based on magnetic and structural characterizations, an increase in coercivity and a decrease in Permalloy film density were observed at the same time. ...
Conference paper (2023) - Veronika Magdanz, Jack R. Cumming, Sadaf Salamzadeh, Sven Tesselaar, Lejla Alic, Leon Abelmann, Islam S.M. Khalil
Magnetic nanoparticles can be electrostatically assembled around sperm cells to form biohybrid micro robots. These biohybrid microrobots possess sufficient magnetic material to potentially allow for pulse-echo localization and wireless actuation. Alternatively, magnetic excitation of these nanoparticles can be used for localization based on Faraday's law of induction using a detection coil. Here, we investigate the influence of the electrostatic attraction between positively charged nanoparticles and negatively charged sperm cells on the activation of the nanoparticles during nonlinear differential magnetometry and wireless magnetic actuation. Activation of clusters of free nanoparticles and nanoparticles bound to the body of sperm cells is achieved by a combination of a high- frequency alternating field and a pulsating static field. The nonlinear response in both cases indicates that constraining the nanoparticles is likely to yield significant decreases in the magnetometry sensitivity. While the attachment of particles to the cells enables wireless actuation (rolling locomotion), the rate of change of the magnetization of the nanoparticles decreases one order of magnitude compared to free nanoparticles ...