14 records found

Journal article (2026) - Zhengyang Xu, Jie Li, Zixuan Zheng, C. Huang, Zheng Ren, Guozheng Shang, Yuntao Sun, Weiwei Miao, Ning Zhou, Yuanzhen Zhu
Due to the spatial mismatch between renewable resources and demand centers in China, cross-regional renewable energy delivery is increasingly constrained by limited capacity of transmission lines, resulting in severe congestion. To exploit flexible resources while ensuring system security, this paper proposes a dynamic feasible region (DFR) characterization approach for tie-line transmission power to support congestion management. A vertex search-based model is developed to iteratively identify the boundary points of the feasible region (FR) in the tie-line transmission power space under security constraints, incorporating multi-type energy storage (ES) regulation and line N-1 security. Based on the identified DFR, an optimization model for congestion management is formulated to enhance tie-line utilization and alleviate line congestion. The obtained optimal configuration of multi-type ES is further utilized for DFR expansion, and multi-resource dispatch strategies are derived through an iterative coordination optimization framework involving repeated DFR reconstruction and congestion management optimization. Case studies conducted on a real-world system in Northern China validate the feasibility and effectiveness of the proposed approach. The results demonstrate that the approach enhances tie-line utilization, improves renewable energy accommodation, and alleviates line congestion in a cost-effective manner. ...
Journal article (2026) - Pingyang Sun, Shan Jiang, Ye Lin, Rongcheng Wu, Hanwen Zhang, Chunjun Huang, Gen Li, Georgios Konstantinou
This paper proposes a Newton-Raphson with search-loop (NR-SL) islanded power flow (IPF) algorithm to solve the PF problem for islanded ac microgrids. The slack bus voltage magnitude in the conventional NR algorithm can be adjusted through the integration of outer search loop also adapting the system frequency. The proposed IPF algorithm also allows for any bus (droop bus, PQ bus, and PV bus) to be a slack bus, since the objective function in the search loop is formulated from the power balance equation at the selected bus. Different derivative-free search approaches, including binary search, golden-section search, and quadratic interpolation search, are independently applied to derive the accurate deviations in system frequency and slack bus voltage magnitude from their initial assumptions. Their convergence behaviour and computational efficiency are then evaluated to identify the most robust approach. Simulation results of a 6-bus ac microgrid demonstrate the accuracy of the proposed NR-SL IPF algorithm, with the quadratic interpolation search achieving the fewest iterations despite being less robust than binary and golden-section search methods. ...
Multi-gigawatt offshore wind-hydrogen energy systems (OWHESs) extend conventional high-voltage direct-current (HVDC)-connected offshore wind power plants (WPPs) by integrating large-scale electrolyzer plants (ELPs), offering a promising decarbonization path through coupling clean offshore wind and green hydrogen. For OWHES dynamic assessment, ELP models scalable to large plant capacities are needed to preserve key electrical dynamics and capture interactions with HVDC links and WPPs. However, existing studies lack an explicit scale-up modeling method for constructing such models, limiting integrated OWHES dynamic assessment. Moreover, existing frequency controls for HVDC-connected WPPs and ELPs are separately developed, without coordinating their complementary responses, leaving OWHES frequency support under-exploited. To address these gaps, this paper develops a module-based aggregated ELP modeling method and a coordinated fast frequency control strategy for OWHESs. The proposed model derives a capacity-scalable plant-level ELP equivalent through an explicit module-to-plant parameter-aggregation formulation, retaining stack, converter, hydrogen-buffer, and controller dynamics while reducing complexity. The proposed control coordinates HVDC, WPP, and ELP active-power responses, enabling fast frequency support and smooth, automatic post-support recovery. An integrated 2 GW OWHES model is established on a real-time simulator for system-level verification. Results demonstrate that the aggregated ELP model reproduces the detailed model with only 0.02% maximum power-response error, verifying the capacity-scalable ELP modeling. Compared with existing methods, the proposed frequency control achieves higher frequency nadir, lower frequency-change rate, and shorter settling time while avoiding deadband-induced oscillations. These results provide a modeling and control basis for offshore wind–hydrogen hubs to enable renewable power–hydrogen coupling while providing grid support. ...

A comparative analysis of single- and dual-stage power interface architectures

Journal article (2026) - Pingyang Sun, Chunjun Huang, Hanwen Zhang, Zihang Qiu, Shu Geng, Kaiwen Sun, Xiaojing Hao
Off-grid power delivery from photovoltaic (PV) systems to electrolyzers serves as a key pathway toward sustainable green hydrogen production, with the PV output voltage adapted to the electrolyzer operating voltage by dc/dc converters. However, a systematic understanding of the performance trade-offs between different converter architectures and their associated control strategies is still lacking, particularly for ensuring robust operation under intermittent solar conditions. This paper presents a systematic comparative study of single- and dual-stage dc/dc converter architectures for standalone PV-electrolyzer (PVEC) systems. The study investigates the fundamental control trade-offs, comparing the single-stage's rigid electrolyzer-following operation with the dual-stage's superior flexibility in providing direct electrolyzer current regulation. To enhance operational resilience, two distinct low power ride-through (LPRT) strategies are proposed and analyzed for the dual-stage configuration, ensuring stable power delivery during significant solar power reductions. The feasibility and performance of the proposed architectures and control strategies are validated through both 5 kW system simulations and experiments on a 200 W GaN-based hardware prototype. The results demonstrate that while the single-stage architecture is viable for small-scale systems, the dual-stage configuration's enhanced control flexibility and scalability are essential for large-scale, storage-ready PVEC applications. ...
Conference paper (2026) - C. Huang, Xin Jin, J.L. Rueda Torres
Offshore wind-hydrogen energy systems (OWHESs) enable large-scale renewable integration and green hydrogen production, playing a pivotal role in the clean energy transition. However, their stable operation critically depends on maintaining internal power balance. This paper addresses the challenge of achieving autonomous coordination of co-located wind-hydrogen plants within OWHES to prevent local power fluctuations from propagating to the offshore network. A coordinated active power control framework is proposed, allowing the co-located plant to operate as a self-balancing unit. The approach employs wind power de-loading to absorb surpluses and electrolyzer load reduction to mitigate deficits, with an intelligent switching mechanism ensuring seamless transitions between control modes. A 2-GW OWHES digital model is built on a commercial real-time simulator to demonstrate the proposed method. Real-time simulation results demonstrate that the proposed control effectively eliminates internal imbalances of the co-located plant, maintaining zero net power exchange with the external offshore network under varying wind and electrolyzer load conditions, thereby ensuring stable nominal power delivery through the HVDC link to onshore systems. ...
Journal article (2026) - Zixuan Zheng, Shijie Li, Chunjun Huang, Zhongmei Li, Yang Wang, Yunzhu Chen, Junhao Ma, Mingshun Zhang, Xianyong Xiao
To address the critical voltage stability of industrial DC microgrids serving sensitive loads, virtual capacitor control is a promising technique for inertia enhancement. However, conventional virtual capacitor control, with its fixed parameters and limited disturbance rejection capability, struggles to maintain qualified voltage quality, threatening the reliable operation of industrial equipment. This paper proposes a novel adaptive virtual capacitor control strategy based on linear active disturbance rejection control (LADRC). The key contribution is a novel control architecture where the virtual capacitor is not predetermined but is adaptively modulated by real-time disturbance estimated by LADRC. This unique feedback mechanism allows the system to proactively counteract both external load changes and internal parameter uncertainties, achieving superior voltage regulation. Furthermore, an integrated sliding time window filter ensures smooth control action by mitigating oscillations from voltage ripple. The proposed strategy's effectiveness in simultaneously enhancing voltage deviation suppression, ripple mitigation, and dynamic inertia support is validated through simulation and hardware-in the-loop (HIL) experiments. ...
Journal article (2026) - N. Narayanan Kuruveettil, C. Huang, M.C. Castrillón Franco, José L. Rueda
When multiple grid-forming and grid-following converters operate within an offshore energy system (OES), dynamic interactions among them can lead to poorly damped oscillations and potential instability. This paper proposes a computationally efficient reduced-order state-space modelling framework for small-signal stability and parametric sensitivity analysis of large-scale OESs. The approach replaces complex full-order analytical modelling with a practical MATLAB/Simulink-based linearisation procedure, enabling tractable stability assessment of systems comprising multiple wind plants, electrolysers, HVDC links and network components. The reduced-order model preserves the dominant dynamics while significantly decreasing the number of states, thereby improving computational efficiency for eigenvalue and sensitivity analyses. Using the linearised model, the influence of key control parameters is systematically quantified to provide explicit guidance for controller tuning and damping improvement. The accuracy of the proposed model is validated through comparison with detailed electromagnetic transient (EMT) simulations in PSCAD/EMTDC, demonstrating close agreement in dynamic responses and stability characteristics. ...

A holistic analytical modeling framework for stability assessment and dynamic interaction

Journal article (2026) - Chunjun Huang, José Luis Rueda Torres, Nakul Narayanan Kuruveettil, Xin Jin
Grid-integrated electrolyzer systems are increasingly deployed for green hydrogen production, which is a promising pathway for energy decarbonization. However, their operation is challenged by insufficiently understood dynamic interactions among the grid-side rectifier, the buck converter, their control loops, and the electrolyzer stack. To address this issue, this paper develops a holistic analytical framework for such systems. A unified model is derived by integrating the rectifier, the buck converter, their control loops, and the electrolyzer stack. Based on this model, eigenvalue, participation-factor, and frequency-response analyses are conducted to systematically quantify stability characteristics, internal dynamic couplings, and parameter sensitivities. For a 2 MW electrolyzer case, the results reveal that excessive rectifier or buck-control bandwidths can independently trigger distinct oscillatory instabilities. On this basis, engineering-oriented controller-tuning guidelines are established, recommending about 10–50 Hz for the phase-locked loop, below about 60 Hz for the DC-link voltage controller, and about 20–150 Hz for the buck power controller. The analysis further shows that properly designed buck bandwidth renders the system-level power response weakly sensitive to slow electrolyzer dynamics dominated by double-layer capacitance, thereby mitigating uncertainty in this capacitance and clarifying the applicability of reduced-order electrolyzer models. These findings are corroborated by PSCAD/EMTDC time-domain simulations, verifying the effectiveness of the proposed analytical model. Additional verifications under frequency and voltage disturbances further confirm the model’s predictive capability, with maximum relative errors of 0.264%–1.486% and 0.153%–5.922%, respectively. Overall, this work offers an efficient analytical tool for stability-oriented control design, model-fidelity selection, and dynamic interaction analysis of grid-integrated electrolyzer systems. ...
Journal article (2026) - Xin Jin, Chunjun Huang, Shi You, Chresten Træholt, Natasa Nord
Large energy storage capacity and low cost of salt hydrates make them ideal candidates for integration into solar water heating systems. In this work, the phase-change performance and system reliability of the sodium acetate trihydrate–acetamide-based system and the sodium acetate trihydrate-based system were experimentally compared. The former system achieved a 5.6% higher efficiency. The system performance was further investigated numerically under varying setpoints and climate conditions to determine the optimal operating conditions for each material. Due to its more efficient use of latent heat, the sodium acetate trihydrate–acetamide-based system achieves a reduction of approximately 3.0% in annual cost compared to the sodium acetate trihydrate-based system at a setpoint of 40°C in Hong Kong. However, the former system shows a longer payback period of approximately 4.9% in Denmark, and both phase-change materials showed negative net present values in France. The sodium acetate trihydrate–acetamide-based system exhibited lower energy use and operating expenditure under solar radiation of around 350–700 W/m2 in Hong Kong. Nevertheless, after accounting for degradation, the higher replacement cost offset its operational savings, leading to a slightly higher lifecycle cost than the sodium acetate trihydrate-based system. This study highlights the importance of climate-specific material selection to balance energy performance and cost-effectiveness. ...

A multi-granularity dispatch disaggregation strategy for isolated microgrid

Journal article (2026) - Jie Li, Zixuan Zheng, Shu Zhang, Xiaomei Yang, Kegeng Zhang, Yongjun Zhou, Chunjun Huang, Xianyong Xiao, Cuomu Yixi, Xiaoming Liu
The operational stability of isolated industrial and mining microgrids is critically challenged by the diverse response characteristics of heterogeneous flexible resources (FRs), such as varying ramp rates and response times. Conventional scheduling methods, which often overlook these multi-granularity attributes, result in significant power imbalances, mismatched execution of the dispatch commands, and degradation of industrial product quality. To address this gap, this paper proposes a novel dispatch command disaggregation strategy for the precise coordination of these resources. The strategy's core innovation begins with establishing a pioneering quantitative flexibility model for lithium mine loads (LMLs), mechanistically exploring the thermo-electric dynamics of the salt-lake lithium extraction process. This specific model is then integrated within a unified framework designed to systematically characterize and quantify the multi-granularity flexibility attributes of diverse resources. Finally, a Discrete Choice Model (DCM) is employed to optimize the dispatch priority of FRs, effectively translating the microgrid's aggregate dispatch command into individualized and feasible setpoints. Validated on a real-world microgrid in Xizang, the proposed strategy reduces system power deviation by 89.05% and decreases the total operating cost by 25.25%. This work provides a practical framework for enhancing the control precision and economic efficiency of isolated microgrids through effective coordination of diverse flexibility assets. ...
Conference paper (2026) - Chunjun Huang, José Luis Rueda Torres
Integrating gigawatt-scale offshore wind-hydrogen energy systems (OWHESs) is pivotal for the energy transition, yet their dynamic interactions and grid-support capabilities remain insufficiently explored. This paper addresses this gap by developing a real-time electromagnetic transient model of a 2 GW OWHES, which is implemented on a commercial real-time digital simulator (RTDS). Furthermore, a novel communication-free coordinated frequency control strategy is proposed, which synergistically harnesses the flexibility of the HVDC system, wind power plants, and electrolyzer plants. Real-time simulation results demonstrate the model's ability to capture the OWHES dynamics. Moreover, results from a significant generation loss scenario demonstrate the proposed control's superiority over existing methods, as it markedly improves the onshore frequency nadir and reduces the rate of change of frequency. This confirms its effectiveness in enhancing onshore frequency stability and showcases the potential of OWHESs as a valuable source of grid ancillary services. ...
Review (2025) - Chunjun Huang, José Luis Rueda Torres, Yi Zong, Shi You, Xin Jin
Power-to-hydrogen systems, particularly the most mature alkaline electrolyzers (AELs), are increasingly deployed in modern energy systems due to their pivotal role in green hydrogen production and decarbonization. Proper modeling is vital for optimizing AEL lifecycle decisions, including design, operation, and investment. Despite numerous proposed models, a review focusing on their applications in system-level decision-making (e.g., operation and planning) remains lacking. This paper bridges this gap by reviewing over 100 peer-reviewed articles to offer an in-depth overview of AEL models employed in system-level decision-making. Followed by clarifying modeling requirements across different levels of AEL system analysis, three types of AEL models are classified in system-level decision-making: linear electricity–hydrogen (LEHM), nonlinear electricity–hydrogen (NEHM), and integrated electricity-heat-hydrogen models (IEHHM). This classification is based on representing the AEL with different levels of multi-physics detail and energy conversion assumptions. LEHM assumes a constant electricity-to-hydrogen conversion efficiency of typically about 60%–70%, while NEHM and IEHHM allow modeling of dynamic efficiency variations in the typical range of 60%–80%, where the IEHHM uniquely integrates thermal dynamics. Their modeling principles, characteristics, strengths, and limitations are systematically reviewed, followed by an in-depth overview of their applications and impacts across four applications: economic operation, grid services, heat recovery, and capacity planning. It reveals that LEHM, NEHM, and IEHHM are employed in 35%, 42%, and 23% of these applications, respectively. Finally, a discussion of current modeling limitations and future direction is provided. This paper offers valuable insights and guidance for selecting appropriate AEL models in decision-making studies and identifying pathways for advancing AEL modeling. ...
Journal article (2025) - Zixuan Zheng, Jie Li, Xiaoming Liu, Chunjun Huang, Wenxi Hu, Xianyong Xiao, Shu Zhang, Yongjun Zhou, Song Yue, Yi Zong
Virtual power plant (VPP) serves as an effective solution for maintaining internal power balance and participating in external peak shaving auxiliary services within grid-connected microgrid involved in multi-type flexible resources (FRs). However, with increasing prominence of the feature heterogeneity in response behaviors of diverse FRs and their coupling in peak shaving poses challenges in the accurate decomposition of VPP scheduling commands. This paper proposes a de-aggregation strategy, utilizing discrete choice model and feature matching methods, to dynamically sequence FRs responses while optimizing VPP's peak shaving capability. Initially, heterogeneous features are refined and modeled to characterize the response capability of multi-type FRs in meeting the scheduled demand of grid-connected microgrid (SDGM). Subsequently, a feature difference quantification model and matching priority criterion are formulated to describe the feature mapping relationship and guide dynamic decision-making process. On this basis, the multi-type FRs are co-scheduled in the considered VPP to form a dynamic response sequence achieving peak shaving objectives. Case studies based on real data from a region-connected microgrid demonstrate the proposed strategy's performance in improving return on investment by 6.1 %, reducing peak shaving deviation and power exchange with main grid by 70 % and 13.1 %, respectively, and effectively improve the ability of grid-connected microgrid to balance the power and participate in peaking auxiliary services. ...
Journal article (2024) - Zixuan Zheng, Shijie Li, Chunjun Huang, Yunzhu Chen, Junhao Ma, Mingshun Zhang, Xianyong Xiao, Jie Ren, Qiang Fu
Energy routers present a viable option for harvesting renewable energy sources (RESs) and ensure dependable electricity provision in industrial microgrids. This paper presents a multi-functional, grid-forming energy router (GFMER), accompanied by a hierarchical proactive control approach. The lower-layer controller handles the coordination strategies among photovoltaic (PV) systems, battery energy storage units (BESU), and DC/AC converters. In this layer, an optimized multi-objective droop control mechanism is presented to proactively regulate AC grid-side voltage imbalances and deviations. Meanwhile, the upper-layer control is deployed to maintain the DC bus voltage, and a novel power allocation module has been designed to enhance the dynamic transient support for grids. The effectiveness and practical value of this proposed methodology have been validated through MATLAB/Simulink and hardware-in-the-loop (HIL) experiments. ...