Jd

J.R. de Jong

info

Please Note

2 records found

A novel approach for optimizing underdosage and overdosage probabilities of target and organ structures

Journal article (2026) - J. R. de Jong, S. Breedveld, S. J. M Habraken, M. S. Hoogeman, D. Lathouwers, Z. Perkó
Objective. Uncertainties in treatment planning are typically managed using either margin-based or robust optimization. Margin-based methods expand the clinical target volume (CTV) towards a planning target volume, which is generally unsuited for proton therapy. Robust optimization considers worst-case scenarios, but its quality depends on the chosen uncertainty (scenario) set: excluding extremes reduces robustness, while including too many make plans overly conservative. Probabilistic optimization overcomes these limitations by modeling a continuous scenario distribution, enabling the use of statistical measures. Approach. We propose a novel approach to probabilistic optimization that steers plans towards individualized probability levels, to control CTV and organs-at-risks (OARs) under- and overdosage. Voxel-wise dose percentiles (d) are estimated by expected value (E) and standard deviation (SD) as E[d] ± δ ⋅ SD[d], where δ is iteratively tuned to match the target percentile of the underlying probability distribution (given setup and range uncertainties). The approach involves an inner optimization of E[d] ± δ ⋅ SD for fixed δ, and an outer optimization loop that updates δ. Polynomial chaos expansion provides accurate and efficient dose estimates during optimization. We validated the method on a spherical CTV (prescribed 60Gy) abutted by an OAR in different directions and a horseshoe-shaped CTV surrounding a cylindrical spine, under Gaussian-distributed setup (3mm) and range (3%) uncertainties. Main results. For spherical cases with similar CTV coverage, P (D 2% > 30 Gy) dropped by 10%–15%; for matched OAR dose, P (D 98% > 57 Gy) increased by 67.5%–71%. In spinal plans, P (D 98% > 57 Gy) increased by 10%–15% while P (D 2% > 30 Gy) dropped by 24%–28% in the same plan. Probabilistic and robust optimization times were comparable for spherical (hours) but longer for spinal cases (7.5–11.5h vs 9–20min). Significance. Compared to discrete scenario-based optimization, the probabilistic approach offered better OAR sparing or target coverage, depending on individualized priorities. ...
Journal article (2026) - J. R. de Jong, S. Breedveld, S. J. M Habraken, M. S. Hoogeman, J. I. de Jong, D. Lathouwers, Z. Perkó
Objective. To show computational feasibility of a previously proposed probabilistic planning approach on a neuro-oncological patient group, we compared probabilistic plans with (automated) robust plans for one patient (group A) that could achieve sufficient clinical target coverage and for four patients (group B) where target coverage had to be compromised due to organ-at-risk (OAR) dose constraints. Approach. The probabilistic approach is percentile-based and uses the fact that a (dose) percentile can be approximated as a linear combination of its expected value and standard deviation. This allows us to formulate objectives and constraints with patient-specific acceptance probabilities. The optimization has a nested structure: the inner optimization optimizes the beam weights for a given percentile estimate, while an outer loop iteratively updates and improves the accuracy of the percentile estimate. For every outer iteration, the optimization is warm-started from the previous iteration. Percentiles are efficiently calculated by sampling a polynomial chaos expansion of the dose-influence matrix. Main results. The patient in group A achieved cumulative OAR dose reductions (of OAR-related DVH-metrics) of 23.1 GyRBE, for identical target coverage. Target coverage improved for all patients in group B (the 10th percentile of (Formula presented) increased up to 0.61 GyRBE), at the same time reaching cumulative OAR dose reductions (of OAR-related DVH-metrics) up to about 40 GyRBE. Probabilistic plans were optimized in 44 h to 226 h. For two representative patients, eliminating warm-starting (i.e. the outer loop) from the approach reduced total optimization times to below 10 h (which took originally 80 h and 141 h). Significance. Compared to robust optimization methods, the probabilistic approach achieves improved trade-offs between probabilistic target coverage and OAR sparing, potentially leading to better treatments. ...