B. Morana
Please Note
30 records found
1
The quantum transduction of an rf/microwave signal to the optical domain, and vice versa, paves the way for technologies that exploit the advantages of each domain to perform quantum operations. Since electro-optomechanical devices implement a simultaneous coupling of a mechanical oscillator to both an rf/microwave field and an optical field, they are suitable for the realization of a quantum transducer. The membrane-in-the-middle setup is a possible solution, once its vibrational mode is cooled down to ultra cryogenic temperature for achieving quantum operation. This work is focused on the mechanical characterization via an optical interferometric probe, down to T = 18 mK , of a loss-shielded metalized membrane designed for this purpose. A stroboscopic technique has been exploited for revealing a mechanical quality factor up to 64 × 10 6 at the lowest temperature. In fact, with continuous illumination and a cryostat temperature below 1 K , the heat due to optical absorption is not efficiently dissipated anymore, and the membrane remains hotter than its environment.
In this work, we present an Opto-Electro-Mechanical Modulator (OEMM) for RF-to-optical transduction realized via an ultra-coherent nanomembrane resonator capacitively coupled to an rf injection circuit made of a microfabricated read-out able to improve the electro-optomechanical interaction. This device configuration can be embedded in a Fabry–Perot cavity for electromagnetic cooling of the LC circuit in a dilution refrigerator exploiting the opto-electro-mechanical interaction. To this aim, an optically measured steady-state frequency shift of 380 Hz was seen with a polarization voltage of 30 V and a Q-factor of the assembled device above (Formula presented.) at room temperature. The rf-sputtered titanium nitride layer can be made superconductive to develop efficient quantum transducers.
Thermal noise is a major obstacle to observing quantum behavior in macroscopic systems. To mitigate its effect, quantum optomechanical experiments are typically performed in a cryogenic environment. However, this condition represents a considerable complication in the transition from fundamental research to quantum technology applications. It is therefore interesting to explore the possibility of achieving the quantum regime in room-temperature experiments. In this work we test the limits of sideband-cooling vibration modes of a SiN membrane in a cavity optomechanical experiment. We obtain an effective temperature of a few millikelvins, corresponding to a phononic occupation number of around 100. We show that further cooling is prevented by the excess classical noise of our laser source, and we outline the road toward the achievement of ground state cooling.
The application of pressure sensors in harsh environments is typically hindered by the stability of the material over long periods of time. This work focuses on the design and fabrication of surface micromachined Pirani gauges which are designed to be compatible with state-of-the-art Silicon Carbide CMOS technology. Such an integrated platform would boost harsh environment compatibility while reducing the required packaging complexity. An analytical model was derived describing the design variables of the Pirani gauges followed by Finite Element Analysis. The Pirani gauges were fabricated in a CMOS compatible cleanroom with a process employing only three masks, thus suitable for mass production. The SiC-based Pirani gauge is far more competitive than the traditional Si-based Pirani gauge in terms of endurance in high-temperature environments. From 25°C to 650°C, the gauge shows a reproducible response to pressure changes and has a maximum sensitivity of $17.63~\Omega $ /Pa at room temperature, and of $1.23~\Omega $ /Pa at 650°C. Additionally, some of the gauges were demonstrated to operate at temperatures up to 750°C.
Feedback-based control techniques are useful tools in precision measurements as they allow us to actively shape the mechanical response of high quality factor oscillators used in force detection measurements. In this paper, we implement a feedback technique on a high-stress low-loss SiN membrane resonator, exploiting the charges trapped on the dielectric membrane. A properly delayed feedback force (dissipative feedback) enables the narrowing of the thermomechanical displacement variance in a similar manner to the cooling of the normal mechanical mode down to an effective temperature Teff. In the experiment reported here, we started from room temperature and gradually increasing the feedback gain, we were able to cool down the first normal mode of the resonator to a minimum temperature of about 124mK. This limit is imposed by our experimental setup and, in particular, by the injection of the read-out noise into the feedback. We discuss the implementation details and possible improvements to the technique.
Micro- and nanomechanical resonators play a prominent part in many sensing and signal processing platforms due to their capability to pervasively couple with a wide variety of physical systems. Particularly relevant is their embedding in advanced optomechanical setups, which has recently pioneered optically cooled mechanical oscillators toward the quantum regime. A frequently adopted experimental scheme exploits a thin, highly tensioned Si 3N 4 nanomembrane where the membrane's vibrations are dispersively coupled to the optical mode of a Fabry-Pérot cavity. A significant effort has been done into realizing high-quality factor membranes, considering that low mechanical loss represents a benchmark to operate in the elusive quantum regime. In this article, we compare two state-of-the-art SiN resonators, realized exploiting the dilution of the material's intrinsic dissipation and efficient solutions to fully isolate the membrane from the substrate. In particular, we examine and discuss the interplay between the edge and distributed dissipation and propose an analytical approach to evaluate the total intrinsic loss. Also, our analysis delves into the sensitivity of the devices to a point-like force and a uniform-density force field. These results provide meaningful guidelines for designing new ultra-coherent resonating devices.
Abstract: Phenomenological models aiming to join gravity and quantum mechanics often predict effects that are potentially measurable in refined low-energy experiments. For instance, modified commutation relations between position and momentum, that account for a minimal scale length, yield a dynamics that can be codified in additional Hamiltonian terms. When applied to the paradigmatic case of a mechanical oscillator, such terms, at the lowest order in the deformation parameter, introduce a weak intrinsic nonlinearity and, consequently, deviations from the classical trajectory. This point of view has stimulated several experimental proposals and realizations, leading to meaningful upper limits to the deformation parameter. All such experiments are based on classical mechanical oscillators, i.e., excited from a thermal state. We remark indeed that decoherence, that plays a major role in distinguishing the classical from the quantum behavior of (macroscopic) systems, is not usually included in phenomenological quantum gravity models. However, it would not be surprising if peculiar features that are predicted by considering the joined roles of gravity and quantum physics should manifest themselves just on purely quantum objects. On the basis of this consideration, we propose experiments aiming to observe possible quantum gravity effects on macroscopic mechanical oscillators that are preliminary prepared in a high purity state, and we report on the status of their realization. Graphical abstract: [Figure not available: see fulltext.].
Recent optomechanical experiments have observed nonclassical properties in macroscopic mechanical oscillators. A key indicator of such properties is the asymmetry in the strength of the motional sidebands produced in the probe electromagnetic field, which is originated by the noncommutativity between the oscillator ladder operators. Here we extend the analysis to a squeezed state of an oscillator embedded in an optical cavity, produced by the parametric effect originated by a suitable combination of optical fields. The motional sidebands assume a peculiar shape, related to the modified system dynamics, with asymmetric features revealing and quantifying the quantum component of the squeezed oscillator motion.
We experimentally investigate a mechanical squeezed state realized in a parametrically modulated membrane resonator embedded in an optical cavity. We demonstrate that a quantum characteristic of the squeezed dynamics can be revealed and quantified even in a moderately warm oscillator, through the analysis of motional sidebands. We provide a theoretical framework for quantitatively interpreting the observations and present an extended comparison with the experiment. A notable result is that the spectral shape of each motional sideband provides a clear signature of a quantum mechanical squeezed state without the necessity of absolute calibrations, in particular in the regime where residual fluctuations in the squeezed quadrature are reduced below the zero-point level.
This work focusses on the design and fabrication of surface micromachined pressure sensors, designed in a modular way for the integration with analog front-end read-out electronics. Polycrystalline 3C silicon carbide (SiC) was used to fabricate free-standing high topography cavities exploiting surface micromaching. The poly-SiC was in-situ doped and the membrane itself is used as piezoresistive element, thereby forming a so-called self-sensing membrane, easing fabrication. After sacrificial release, the cavity is sealed by conformal deposition of poly-SiC whereby the reference pressure of the absolute pressure sensor is determined. Aluminum and titanium metallizations were used and ohmic contacts were confirmed by wafer-scale measurements. Measurements were carried out on different devices ranging from 100 kPa down to 10 Pa at room temperature. The Wheatstone bridge yields a logarithmic response of 1.1 mVbar-1 V-1. A square 300 μ m device exhibits a logarithmic impedance behavior yielding a response of Δ R/R of 1.6× 10-3 bar-1. The realized pressure devices are a first step toward a SiC ASIC + MEMS platform for intended operation in harsh environments, such as industrial process monitoring, combustion control or structural health monitoring. The future outlook of the integration concept implies extended functionality by front-end transducer read-out, signal amplification and communication.
We describe a method to control the cavity detuning in optomechanics experiments. This helps accurate measurements of the asymmetry in the motional sidebands, that testify the quantum behavior of the oscillator and quantifies its occupation number.
Cavity optomechanics has achieved the major breakthrough of the preparation and observation of macroscopic mechanical oscillators in non-classical states. The development of reliable indicators of the oscillator properties in these conditions is important also for applications to quantum technologies. We compare two procedures to infer the oscillator occupation number, minimizing the necessity of system calibrations. The former starts from homodyne spectra, the latter is based on the measurement of the motional sideband asymmetry in heterodyne spectra. Moreover, we describe and discuss a method to control the cavity detuning, that is a crucial parameter for the accuracy of the latter, intrinsically superior procedure.
The high aspect ratio and the porous nature of spatially oriented forest-like carbon nanotube (CNT) structures represent a unique opportunity to engineer a novel class of nanoscale assemblies. By combining CNTs and conformal coatings, a 3D lightweight scaffold with tailored behavior can be achieved. The effect of nanoscale coatings, aluminum oxide (Al2O3) and nonstoichiometric amorphous silicon carbide (a-SiC), on the thermal transport efficiency of high aspect ratio vertically aligned CNTs, is reported herein. The thermal performance of the CNT-based nanostructure strongly depends on the achieved porosity, the coating material and its infiltration within the nanotube network. An unprecedented enhancement in terms of effective thermal conductivity in a-SiC coated CNTs has been obtained: 181% compared to the as-grown CNTs and Al2O3 coated CNTs. Furthermore, the integration of coated high aspect ratio CNTs in an epoxy molding compound demonstrates that, next to the required thermal conductivity, the mechanical compliance for thermal interface applications can also be achieved through coating infiltration into foam-like CNT forests.
Optomechanical SiN nano-oscillators in high-finesse Fabry-Perot cavities can be used to investigate the interaction between mechanical and optical degree of freedom for ultra-sensitive metrology and fundamental quantum mechanical studies. In this paper, we present a nano-oscillator made of a high-stress round-shaped SiN membrane with an integrated on-chip 3-D acoustic shield properly designed to reduce mechanical losses. This oscillator works in the range of 200 kHz to 5 MHz and features a mechanical quality factor of Q ≃ 107 and a Q-frequency product in excess of 6.2 × 1012 Hz at room temperature, fulfilling the minimum requirement for quantum ground-state cooling of the oscillator in an optomechanical cavity. The device is obtained by MEMS deep reactive-ion etching (DRIE) bulk micromachining with a two-side silicon processing on a silicon-on-insulator wafer. The microfabrication process is quite flexible such that additional layers could be deposited over the SiN membrane before the DRIE steps, if required for a sensing application. Therefore, such oscillator is a promising candidate for quantum sensing applications in the context of the emerging field of quantum technologies.
The extraordinary sensitivity of the output field of an optical cavity to small quantum-scale displacements has led to breakthroughs such as the first detection of gravitational waves and of the motions of quantum ground-state cooled mechanical oscillators. While heterodyne detection of the output optical field of an optomechanical system exhibits asymmetries which provide a key signature that the mechanical oscillator has attained the quantum regime, important quantum correlations are lost. In turn, homodyning can detect quantum squeezing in an optical quadrature but loses the important sideband asymmetries. Here we introduce and experimentally demonstrate a new technique, subjecting the autocorrelators of the output current to filter functions, which restores the lost heterodyne correlations (whether classical or quantum), drastically augmenting the useful information accessible. The filtering even adjusts for moderate errors in the locking phase of the local oscillator. Hence we demonstrate the single-shot measurement of hundreds of different field quadratures allowing the rapid imaging of detailed features from a simple heterodyne trace. We also obtain a spectrum of hybrid homodyne-heterodyne character, with motional sidebands of combined amplitudes comparable to homodyne. Although investigated here in a thermal regime, the method's robustness and generality represents a promising new approach to sensing of quantum-scale displacements.
A surface-acoustic-mode aluminum nitride (AlN) transducer is utilized to determine the type of liquid dropped on the propagation path. It is based on tracking the shrinking droplet radius and observing stagnant liquid molecules during and after the liquid evaporation process. The device configuration is suitable to test small amounts of liquids, in the microliter range. According to both mass loading and physical property mechanisms, eight samples of liquids, isopropanol (IPA), ethanol (ETH), deionized-water (DW), tap water (TW), heptane (HEP), propylene glycol monomethyl ether acetate (PGMEA), hexamethyldisilazane (HMDS) and acetone (ACE), which have different equilibrium vapor pressures, molecular weights and boiling points, are accurately detected. The experimental results show that the rate of the change in the energy loss including a slow and fast attenuation region depends on the change of physical properties, such as density, sound speed in liquids and evaporation rate, during the evaporation process. As the evaporation rate of the DW is rather slow, the slow attenuation region occurs for a longer time than the fast one. Consequently, the whole oscillation duration of the attenuation occurs for a longer time, whereas that of the other liquids studied, like ACE, ETH, and IPA, having a faster evaporation rate is shorter. Sensitivities of the surface-acoustic-mode transducer to the evaporation process of liquids such as DW, TW, PGMEA, HMDS, HEP, IPA, ETH and ACE are −29.39, −29.53, −31.79, −34.12, −33.62, −32.87, −32.67, and −32.82 dB μm−2, respectively. The concentration of stagnant liquid molecules causes a change in the surface mass of the micro-electro-mechanical transducer, which causes a frequency shift and increases the signal noise at the receiver after the liquid evaporation process. The average frequency shifts of ACE, HEP, HMDS, ETH, IPA, PGMEA, TW and DW are 241, 206, 172, 117, 76, 27.3, 11.6 and 0 kHz, respectively, coherent with the type of formed liquid pattern on the device surface, thus allowing to detect liquid samples effectively.
An unprecedented enhancement in electrical conductivity of horizontally aligned carbon nanotube (HA-CNT) structures using a 10 nm conformal coating of alumina (Al2O3) or amorphous silicon carbide (a-SiC) is presented. By combining the capability to grow long vertically aligned CNTs (VA-CNTs) with a liquid-assisted flattening technique, dense arrays of HA-CNTs exhibiting a high degree of alignment are realized and integrated at wafer-scale. Suspended structures, ranging from large area membranes to narrow beams, can be fabricated. The impressive enhancement in electrical conductivity, approximately 209% for the Al2O3 coated HA-CNTs (Al2O3/HA-CNTs) and 2276% for the a-SiC ones (a-SiC/HA-CNTs), demonstrates the potential of CNT-based scaffolds as scalable and functional building blocks for suspended interconnects, heat spreaders and novel chemical and optical sensors.
The effect of the contact angle and radius of a microsize droplet on the surface acoustic wave (SAW) response for microfluidic applications is reported. It is studied through the dynamic change of the droplet shape during the evaporation process. An aluminium nitride SAW device, operating at 125.7 MHz, is utilized to investigate the deformation of the droplet shape (contact angle and contact radius) caused by shrinking. The large cavity placed on the propagation path distorts the in-band SAW response one time at the centre frequency. The fractional coefficient of the SAW insertion loss, before and after dropping the liquid on the propagation path, is continuously recorded. The change in the fractional coefficient shows that the radiated acoustic kinetic energy depends on the contact area between the sessile micro-size droplet and the SAW device more than the contact angle of the droplet. Three droplet volumes have been considered, namely 0.05, 0.1 and 0.13 μl, and the electrical results show a better agreement with the theoretical data than the optical image data. The average duration of the fractional coefficient change for these cases is 420, 573 and 760 s, respectively. The effect of the hydrophobicity versus hydrophilicity of the contact surface on the duration of the fractional coefficient change is studied by coating the SAW with a silicon oxide or hexamethyldisilazane (HMDS) thin layer. For the same 0.05 μl sessile droplet on the hydrophobic surface, this duration is on average 110 s longer than that on the hydrophilic surface.