All-fiber-optic LIBS system for tissue differentiation

A prospect for endoscopic smart laser osteotomy

Minimally-invasive laser surgeries could benefit from a fiber-optic laser-induced breakdown spectroscopy (FO-LIBS) setup for real-time tissue characterization. In FO-LIBS, the sample receives limited light irradiance due to the fiber's low damage threshold and diminished laser be ...
To obtain efficient laser ablation in bone, dehydration, early carbonization and carbonization need to be avoided. Achieving this can only be provided by using an automated control of the ablation laser and irrigation system. As a preliminary study, we demonstrated a laser-induce ...
Minimally invasive laser surgeries that require the use of a flexible endoscope (flexiscope) could benefit from high-energy nanosecond laser pulses delivered through fibers for real-time tissue characterization and phenotyping. The damage threshold of the fiber's glass material l ...

Robot- and laser-assisted bio-sample preparation

Development of an integrated, intuitive system

The preparation of small-sized biological samples is traditionally performed manually utilizing mechanical tools such as scalpels. The main drawbacks of such methods are a lack of accuracy and repeatability of the resulting cuts and damage to the surrounding tissue due to the hig ...
Echelle spectrometers offer high-resolution (ca. one Angstrom or higher) and wide range (ca. half a micron or wider), simultaneously, without having a mechanical moving part. However, they require a complicated optical set-up as compared to conventional one-dimensional-dispersion ...
Preparation of biological samples for further processing or analysis is generally performed manually by means of standard mechanical tools such as scalpels or biopsy punches. While this approach is uncomplicated and swift, it entails constraints such as low, operator-dependent cu ...
A novel real-time and non-destructive method for differentiating soft from hard tissue in laser osteotomy has been introduced and tested in a closed-loop fashion. Two laser beams were combined: a low energy frequency-doubled nanosecond Nd:YAG for detecting the type of tissue, and ...
During the past half-century, laser osteotomy has been studied for a broad range of lasers, which almost covers the entire range of available laser systems in the market, from early unsuccessful experiments with CW lasers to newly developed ultrashort pulse lasers. Although a lar ...
A cost-effective method employing a smartphone sensor to measure the laser-induced sound pressure level (SPL) has been introduced for lens-to-sample distance (LTSD) adjustment in micro laser-induced breakdown spectroscopy (µLIBS).@en
In laserosteotomy, it is vital to avoid thermal damage of the surrounding tissue, such as carbonization, since carbonization does not only deteriorate the ablation efficiency but also prolongs the healing process. The state-of-the-art method to avoid carbonization is irrigation s ...
In minimal invasive laser osteotomy precise information about the ablation process can be obtained with LIBS in order to avoid carbonization, or cutting of wrong types of tissue. Therefore, the collecting fiber for LIBS needs to be optimally placed in narrow cavities in the endos ...
Although laserosteotomes have become generally accepted devices in surgical applications, they still suffer from a lack of information about the type of tissue currently being ablated; as a result, critical structures of the body under or near the focal spot of the laser beam are ...
The aim of this paper is to examine the effect of pig bone immersion in different levels of cooling water during laser ablation with a Er:YAG laser. The laser worked at 2940 nm wavelength and 10 Hz repetition rate in microseconds pulse duration regime. The bone was immersed in di ...
The aim of the present study is to investigate the effect of laser pulse duration on ablation efficiency of hard bones. The bones were ablated using a microsecond pulsed Er-YAG laser. The laser wavelength was 2.94 μm and the repetition rate was 10Hz. Three samples of porcine femu ...