Lift Estimation from Wind Tunnel Wall Pressure
An experimental approach carried out at the Research & Development department of Econowind
J.P. Tillie (TU Delft - Aerospace Engineering)
F. Scarano – Mentor (TU Delft - Aerospace Engineering)
A. Daliri Rezagholigheshlaghi – Mentor (TU Delft - Aerospace Engineering)
More Info
expand_more
Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.
Abstract
At Econowind, wind-tunnel testing is used to evaluate the aerodynamic performance of boundary-layer suction wings, with lift primarily determined through wall pressure measurements (WPM).
A baseline experiment was conducted using a NACA0015 airfoil without suction. Lift coefficients obtained from WPM were compared with independently derived surface pressure measurements (SPM) at Reynolds numbers of Re=200,000, Re=400,000, and Re=600,000.
The results show good agreement between WPM and SPM in the pre-stall regime, while discrepancies increase around stall and become substantial in the post-stall region, where WPM consistently overpredicts lift relative to SPM.
Further analysis revealed that the measured wall-pressure footprint alone yields lift estimates close to those obtained from SPM in the post-stall regime, whereas the existing corrections and empirical extrapolations generally lead to overprediction.
These findings demonstrate the potential of WPM for lift estimation under predominantly attached-flow conditions while identifying strongly separated flow as a major limitation of the current approach.