Thermal behavior of a concrete recycling unit during the transition from diesel-fired to electric hot air generator

Journal Article (2026)
Author(s)

Nishab Ali (TU Delft - Civil Engineering & Geosciences)

Osama Zaid (TU Delft - Civil Engineering & Geosciences)

Abraham Teklay Gebremariam (TU Delft - Civil Engineering & Geosciences)

Arun Chand (Indian Institute of Technology Roorkee)

Andallib Tariq (Indian Institute of Technology Roorkee)

Research Group
Resources & Recycling
DOI related publication
https://doi.org/10.1016/j.csite.2026.107741 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Resources & Recycling
Journal title
Case Studies in Thermal Engineering
Volume number
79
Article number
107741
Page Views
4
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

For the advancement of sustainable and cleaner operation in concrete recycling, the Heating Air Classification System (HAS) requires replacing the existing diesel-fired burner with an electric heating technology. This study contributes to that transition by evaluating the suitability of electric hot air generators for HAS operational thermal needs. Through detailed numerical analysis, the thermal performance and flow behavior of HAS are assessed across single (Cases: A1–A4) and dual inlet (Cases: B1–B4) configurations, and for a range of hot air inlet temperatures (800–950 °C). Spatial distributions of normalized temperature, velocity, and turbulent kinetic energy (TKE) are examined on multiple planes to characterize flow behavior, heating uniformity, and mixing. The results show that an electric hot air generator can nearly match the mean bulk temperature (⟨T/T0⟩ ≈ 0.49–0.50) achieved with diesel systems, while providing notable improvements in thermal uniformity. Among all studied scenarios, the dual inlet configuration with lower hot air injection temperature (B1) achieves the lowest standard deviation (0.080) and coefficient of variation (0.162), ensuring the most consistent heating and minimal thermal gradients. These findings highlight that an electric hot air generator can be seen as one of the promising electrification pathways for HAS, supporting enhanced energy efficiency and cleaner production in concrete recycling applications.