Re-strike and re-ignition effects of HVDC VARC DC breaker

Journal Article (2026)
Author(s)

Ajay Shetgaonkar (TU Delft - Electrical Engineering, Mathematics and Computer Science, TenneT TSO B.V.)

Marjan Popov (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Research Group
Intelligent Electrical Power Grids
DOI related publication
https://doi.org/10.1049/icp.2026.2280 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Intelligent Electrical Power Grids
Journal title
IET Conference Proceedings
Issue number
4
Volume number
2026
Pages (from-to)
101-108
Event
22nd IET International Conference on AC and DC Power Transmission, ACDC Europe 2026 (2026-04-28 - 2026-04-29), Berlin, Germany
Page Views
82
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

The transition to renewable energy requires robust High Voltage Direct Current (HVDC) technology. This paper examines the performance of Voltage Source Converter-Assisted Resonant Current (VARC) Direct Current Circuit Breakers (DC CBs) during re-strike and re-ignition events, which can compromise their ability to selectively isolate faults in Multi-Terminal HVDC (MTDC) networks. The paper analyzes re-strike effects on VARC DC CBs during two breakdown scenarios, noting that parallel surge arresters maintain voltage balance among health-operational modules. In contrast, individual arresters in healthy modules endure stress when vacuum interrupters VIs fail to interrupt the current. The role of the Voltage Source Converter (VSC) in VARC DC CBs is also emphasized, with findings that adequate energy in the VSC branch is essential for effective current interruption. The study further investigates re-strike impacts during the Transient Interruption Voltage (TIV) and fault current suppression time, observing that random re-strikes can compromise DC CB integrity, underscoring the need for design considerations to address such events. These findings advance the understanding of DC CB performance and reliability of MTDC networks, offering critical insights for developing resilient protection systems in the renewable energy transition. This study stresses the importance of managing re-strike and re-ignition in VIs and provides valuable guidance for designing and assessing DC CBs in MTDC applications.