On Azimuth Ambiguities Suppression for Short-Baseline Along-Track Interferometry
The Stereoid Case
More Info
expand_more
expand_more
Abstract
Ambiguities in short-baseline ATI interferometry need to be treated not as noise that lowers the coherence, but as a source of bias. A mathematical formulation of the interferometric ambiguity model is given, and an approach to correct ambiguities is proposed and illustrated with simulation results.