Design and Demonstration of a Gravitational Compensator Using a Coupled Hybrid Tunable Magnet Actuator
A.A. Gunnarsson (TU Delft - Mechanical Engineering)
S.H. Hossein Nia Kani – Mentor (TU Delft - Mechanical Engineering)
E.P. Ronæs – Mentor
More Info
expand_more
Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.
Abstract
Magnetic actuators are widely used in precision mechatronic systems such as gravity compensators due to their frictionless operation and suitability for vacuum environments. However, conventional Lorentz and reluctance actuators remain limited; Lorentz actuators offer linearity and zero stiffness but exhibit low force density and significant Joule heating. Reluctance actuators provide high force density but require continuous power and show strong nonlinearities. Actuators that exploit their hysteresis offer the ability to generate static forces without sustained current, but each approach suffers from constraints in efficiency, tuning times, varying forces, and levitation heights. Recent work introduced a combination of the Hybrid Tunable Magnet Actuator (HTMA) and Hybrid Reluctance Actuator (HRA), enabling both static flux generation and dynamic force control. This paper reports the design, modelling, construction and characterisation of a compensator combining a HTMA with two HRAs, sharing one mover and four biasing magnets within a 100 × 80 × 100 mm envelope. The geometry was selected by a sensitivity study of eight parameters, expressed as elasticities of force, stiffness and loadline metrics, supported by a magnetic equivalent circuit and a finite-element model. The model predicts ±163 N over ±1 mm of travel, with 50 N available throughout ±0.5 mm, and a stiffness variation of 11.2 N mm−1 along the 50 N locus that no linear flexure can remove and that the reluctance actuators can cancel at a commanded gradient of 0.76 A mm−1. The demonstrator produces the specified 50 N with no current in the tunable-magnet coil, at a reluctance force constant of 7.2 N A−1 against the predicted 14.8 N A−1, despite an air gap degraded by deflection of the fixture. The stiffness could not be verified: the pedestal carrying both the stators and the measurement datum deflects under load, so the recorded displacement is not the change in air gap.
Files
File under embargo until 30-11-2028