From Building Archetypes to Data-Driven Definitions

The Impact of Window-to-Wall Granularity on Urban Building Energy Modelling

Journal Article (2026)
Author(s)

Camilo León-Sánchez (Wageningen University & Research)

Taşkın Özkan (TU Delft - Architecture and the Built Environment)

Giorgio Agugiaro (TU Delft - Architecture and the Built Environment)

Research Group
Urban Data Science
DOI related publication
https://doi.org/10.5194/isprs-archives-L-4-W3-2026-83-2026 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Urban Data Science
Journal title
International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences - ISPRS Archives
Issue number
4/W3-2026
Volume number
50
Pages (from-to)
83-90
Event
10th International Conference on Smart Data and Smart Cities, SDSC 2026 (2026-09-29 - 2026-10-01), Sofia, Bulgaria
Page Views
28
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This research investigates how window-to-wall ratio (WWR) granularity affects urban building energy modelling for Positive Energy District planning. We use surface-level WWR data extracted from oblique aerial imagery and compare the resulting simulation outputs against fixed district-average and generic WWR assumptions across two neighbourhoods: Feijenoord and Prinsenland, in Rotterdam, The Netherlands. The analysis uses harmonised building data, adapted to the specific requirements of CitySim and SimStadt simulation tools to evaluate each tool independently against a baseline. Results indicate that fixed WWR assumptions significantly distort simulated energy profiles. The highest effects occur for cooling demand: applying a fixed 20% WWR leads to an increase in the cooling demand by 106.2% in Feijenoord and 127.8% in Prinsenland using CitySim. Such behaviour happens as well in SimStadt, where cooling demand values increase by 67.2% and 68.5%, respectively. Building-level distributions reveal even stronger local deviations, particularly where baseline cooling demand is low. Finally, the findings show that while neighbourhood-average WWR values reduce aggregate error relative to generic assumptions, they still obscure building-specific peaks that are critical for accurate district energy planning.