Suitability of Single-Machine Dynamic Equivalent Model for Large Offshore Renewable Plant

Conference Paper (2026)
Author(s)

Harshit Nayak (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Jose Luis Rueda Torres (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Peter Palensky (TU Delft - Electrical Engineering, Mathematics and Computer Science, TU Delft - Electrical Engineering, Mathematics and Computer Science)

Research Group
Intelligent Electrical Power Grids
DOI related publication
https://doi.org/10.1109/GPECOM70462.2026.11578575 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Intelligent Electrical Power Grids
Pages (from-to)
521-526
Publisher
IEEE
ISBN (electronic)
9798331552046
Event
8th Global Power, Energy and Communication Conference, GPECOM 2026 (2026-06-03 - 2026-06-05), Naples, Italy
Page Views
81
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

The expansion of offshore wind power plants (OWPP) necessitates power system studies of wind power plant due to large number of interfaced converters in wind turbine. The traditional detailed model of wind farms although provides high fidelity but leads to computational complexity and long simulation time. Due to this, simplified equivalent modeling approaches such as the single-machine (SM) equivalent model are commonly adopted in the system studies. This approach considers similar wind incident on all turbines and ignores the losses due to collector cables which is unsuitable due to the complexity and scaling of the network. However, the suitability of such equivalent representation for large OWPPs under multiple-event scenarios remains insufficiently examined in the existing literature. Therefore, this paper investigates the dynamic suitability of a single-machine and multi-machine equivalent model for a 400 MW HVDC-connected OWPP in DIgSILENT PowerFactory. Both aggregated models are examined against each other and the detailed WPP under sequential event scenarios. The comparison is performed based on the RMS dynamic response as well as quantitative performance metrics such as root mean square error (RMSE) and fit percentage. The results indicate that the SM equivalent model only captures the dominant dynamic behavior and reduces the computation time by 84%, whereas the multi-machine model provides an improved accuracy for transient response with a reduction of computation time by 77%.