GR

Gert Rietveld

19 records found

This paper comprehensively reviews several techniques that address the static and dynamic voltage balancing of series-connected MOSFETs. The effectiveness of these techniques was validated through simulations and experiments. Dynamic voltage-balancing techniques include gate sign ...
Closed-form solutions are presented for calculating the reflection coefficient with corresponding uncertainty of metrology-grade 3.5 mm air-dielectric coaxial transmission lines for use as reference standards in S-parameter measurements up to 33 GHz. The closed-form solutions all ...
This paper deals with the essentials of synchrophasor’s applications for future power systems to increase system reliability and resilience, which have been investigated within a four-year research project. The project has several applications, covering real-time disturbance dete ...
In the future, series-connected SiC MOSFETs will become widely used in power-electronic-based medium and high voltage (HV) applications such as modular multilevel converters (MMCs). Balanced voltage sharing among the SiC MOSFET string is hard to be achieved due to possible deviat ...
The addition of RF interferometers to vector network analyzer (VNA) test benches has allowed for realization of low-noise high-frequency measurements of extreme impedance devices. However, when employing correction techniques such as the short-open-load method, the RF response of ...
A method is presented for automated probing of on-wafer devices for measurements at millimetre-wave frequencies. The proposed method automatically detects the contact between the measurement probe and on-wafer device, based on the evaluation of variation in the input reflection c ...
This paper analyzes and accurately models the complex noise behavior of vector network analyzers (VNAs) when measuring large-mismatch devices and subsequently shows how the VNA measurement noise performance is enhanced through implementation of a high-speed, broadband, active RF ...
Methods for traceable characterization and uncertainty evaluation of planar I-port CPW short-open-Ioad (SOL) devices are developed. The agreement of modelling and verification measurement results greatly supports the application of the proposed parameterization models and used FE ...
The installation of phasor measurement units (PMUs) by Enduris, one of the distribution network operators in the Netherlands to monitor their 50 kV ring distribution grid has resulted in increased observability of the power flows and voltages. However, with the increased observab ...
This paper presents a comparison between two different approaches to fault location both with and without utilising transmission line parameters. Firstly, an impedance-based parameter-dependent algorithm, derived by using modal transformation theory and fast Fourier transform is ...